Status
RESET button projects from the tool casing. Its
white edge is visible.
RESET button is flush with the tool casing.
3.9 Support leg
On an even working surface, the support leg makes it easier to hold the fastening tool perpendicular as
attention then only has to be paid to lateral alignment. On an uneven or undulating surface it may be necessary
to remove the support leg in order to allow the fastener guide to be held perpendicular to the working surface.
3.10 Belt hook
The belt hook can be extended in two stages.
Status
First position
Second position
3.11 Gas can
Note
Observe the safety instructions provided with the gas can!
In order to operate the fastening tool, the gas can must be inserted in the gas can compartment.
The gas can status can be read from the LED display after pressing the GAS button.
The gas can must be removed before breaks between working, before maintenance and before transporting
or storing the fastening tool.
3.12 Indication of gas can status
After pressing the GAS button, the LED display indicates the status of the gas can.
Note
The fill level indicator does not operate correctly if the fastener guide has been fully plunged into the tool.
Status
All four LEDs light green.
Three LEDs light green.
Two LEDs light green.
One LED lights green.
One LED blinks green.
One LED lights red.
4 Technical data
4.1 Fastening tool
Weight (empty)
Application temperature, ambient temperature
Maximum fastener length
Meaning
Piston position is incorrect
Piston position is correct
Meaning
Position for attaching to a waist belt
Position for attaching to ladders, scaffolds,
platforms, etc.
Meaning
Level is approx. 100 %.
Level is approx. 75 %.
Level is approx. 50 %.
Level is approx. 25 %.
Level is below 10 %. Replacement of the gas
can is recommended.
There is either no gas can in the setting tool,
the wrong type of gas can is fitted or the can is
empty.
Note
Even when the level is indicated as "empty", the
gas can, for technical reasons, still contains a little
gas.
3.9 kg
−10 ℃ ... 45 ℃
39 mm
19

Publicité

loading

Ce manuel est également adapté pour:

Gx 3-me