BY UNITED STATES STOVE C
O
-
E Backwall to unit
F Sidewall to flue
PARALLEL
Sidewall to top edge
G
of unit
H Backwall to flue
CORNER
J Adjacent wall to unit
ALCOVE
K Alcove depth
OUTSIDE AIR SUPPLY
INSTALLING IN A MOBILE HOME/TRANSPORTABLE BUILDING)
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home/
transportable building. You can purchase the 69FAK
through your heater dealer. Installation instructions are
supplied with the air intake kit.
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK,
AWNING, OR IN ANY SEMI ENCLOSED OR
ROOFED AREA. DOING SO MAY RESULT IN
UNPREDICTABLE AIRFLOW AT THE VENT CAP
UNDER CERTAIN CONDITIONS AND CAN AFFECT
THE PERFORMANCE OF YOUR STOVE, AS WELL
AS, OTHER UNFORESEEABLE ISSUES.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the floor.
Fresh Air
Intake
© 2024 United States Stove Company
K
9.5"
241 mm
13"
330 mm
8"
203 mm
3"
76.2 mm
8"
203 mm
36"
914 mm
(OPTIONAL, UNLESS
Exhaust
Pipe
WARNING! DO NOT INSTALL IN SLEEPING ROOM.
CAUTION! THE STRUCTURAL INTEGRITY OF THE
MOBILE
HOME/TRANSPORTABLE
FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
WHEN
INSTALLED
TRANSPORTABLE BUILDING, THE STOVE MUST
BE GROUNDED DIRECTLY TO THE STEEL CHASSIS
AND BOLTED TO THE FLOOR.
In addition to the previously detailed installation
requirements,
mobile
installations must meet the following requirements:
• This stove must be securely fastened to the floor of the
mobile home/transportable building using two 1/4" lag
bolts that are long enough to go through both a hearth
pad, if used, and the floor of the home.
• The heater must be electrically grounded to the steel
chassis of the mobile home/transportable building
with 8 GA copper wire using a serrated or star washer
to penetrate paint or protective coating to ensure
grounding.
• Vent must be 3 or 4-inch "PL" Vent and must extend
a minimum or 36" (914 mm) above the roof line of
the mobile home/transportable building and must be
installed using a certified ceiling fire stop and rain cap.
• When
moving
your
building, all exterior venting must be removed while the
mobile home/transportable building is being relocated.
After relocation, all venting must be reinstalled and
securely fastened.
• Outside Air is mandatory for mobile home/transportable
building installation. See Outside Air Supply section
and your dealer for purchasing.
• Check with your local building officials as other codes
may apply.
VENTING REQUIREMENTS
A compatible appliance adapter is required for the proper
venting installation of this unit. Purchase the appropriate
appliance adapter from your preferred venting company
prior to starting the ventilation process.
8
INSTALLATION
BUILDING
IN
A
MOBILE
HOME/
home/transportable
mobile
home/transportable
building