Télécharger Imprimer la page

Publicité

Liens rapides

Owner's Instruction and Operation Manual
Model Number:
5710-XH
Report Number: F19-549
Certified to ASTM E1509-12 (2017)
and Certified to ULC-S627-00-REV1
Mobile Home Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
853866B-0204K
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour United States Stove 5710-XH

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2021 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 Your stove is Certified to ASTM E1509-12 (2017)and Certified to ULC S627-00. This manual describes the installation and operation of the U.S. Stove, 5710-XH wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 13,281 to 27,492 Btu/hr.
  • Page 3 Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: ______________________________________ Print Name: __________________________________Date: ______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2021 United States Stove Company...
  • Page 4 2. Unpack the top mount controls and ensure that the wiring harness shown is attached securely. 4. Secure the control panel to the top of the stove with two sheet metal screws. © 2021 United States Stove Company...
  • Page 5 CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE. US Stove highly recommends your stove be installed by a qualified NFI (US) or WETT (Canada) technician. To find the nearest qualified installer, go to: https://nficertified.org, https://www.wettinc.ca/ © 2021 United States Stove Company...
  • Page 6 191 mm U.S.A 6” 153 mm Front to Stove Side Wall to Vent Pipe 11-1/4” 286 mm 8” 204 mm Back Wall to Vent Pipe 7-1/2” 191 mm Back to Flue 2” 51 mm © 2021 United States Stove Company...
  • Page 7 The maximum recommend vertical venting height is 12- home. feet for 3-inch type “PL” vent. Total length of horizontal © 2021 United States Stove Company...
  • Page 8 Vent surfaces can get hot enough E. Minimum 2-foot (0.61m) clearance above any grass, to cause burns if touched by children. Noncombustible plants, or other combustible materials. shielding or guards may be required. © 2021 United States Stove Company...
  • Page 9 18” (457 mm) above ground level, a an offset is required, it is better to install 45-degree straight section of pellet vent pipe can be used through elbows rather than 90-degree elbows. © 2021 United States Stove Company...
  • Page 10 The fuel adjuster is located inside the hopper. the bar graph starting from heat range “1” to heat range Note: The factory default setting for this is full open. To “5”. decrease the flow of pellets, move the fuel adjuster down. © 2021 United States Stove Company...
  • Page 11 10. Salt water driftwood or other previously salt water Pellets can be screened before being placed in hopper saturated materials; to remove most fines. 11. Unseasoned wood; or © 2021 United States Stove Company...
  • Page 12 Fill hopper and clean burn pot. to re-start your stove. The stove will have to fully shut 2. Press “On/Off” button. Make sure green light comes down and turn off before you will be able to restart the stove. © 2021 United States Stove Company...
  • Page 13 WARNING: able to restart the stove NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT FROM THE POWER SOURCE. Turning your stove off is a matter of pressing the “POWER” © 2021 United States Stove Company...
  • Page 14 Some regular vacuum cleaner Clean-Out (i.e. shop vacs) may leak ash into the room. DO NOT VACUUM HOT ASH. Plate WARNING: FAILURE TO PROPERLY MAINTENANCE THE CLEAN OUTS WILL RESULT IN POOR PERFORMANCE OF THIS STOVE. © 2021 United States Stove Company...
  • Page 15 CO emitted inspected, cleaned and, if necessary, repaired. To clean out the chimney, exposure to the gases in closed or the chimney, disconnect the vent from the stove. © 2021 United States Stove Company...
  • Page 16 The exhaust system should be NOT use abrasive cleaners. DO NOT perform the cleaning thoroughly cleaned. while the glass is HOT. Do not attempt to operate the unit © 2021 United States Stove Company...
  • Page 17 Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email parts@usstove.com. Model Information Model Number Serial Number © 2021 United States Stove Company...
  • Page 18 If the other items check out OK, replace the high limit switch. ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2021 United States Stove Company...
  • Page 19 (you may want to remove the hose entirely off the stove and the air switch first and make sure it is clear). If you hear a click, the air switch is working. BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH. © 2021 United States Stove Company...
  • Page 20 The control board is not sending power to the POF There should be a 5-volt (approximately) current going to the thermodisc or other auger system components. POF thermodisc after the stove has been on for 10 minutes. © 2021 United States Stove Company...
  • Page 21 Remove the auger motor from the auger shaft and try to run the The auger motor has failed. unit. If the motor will turn the shaft is jammed on something. If the motor will not turn, the motor is bad. © 2021 United States Stove Company...
  • Page 22 Circuit board malfunction. board is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board. © 2021 United States Stove Company...
  • Page 23 Check to see if a surge protector is being used on the stove. If not, recommend one to the consumer. High limit switch is malfunctioning. If the other items check out okay, replace the high limit switch. © 2021 United States Stove Company...
  • Page 24 Bad Pellets. (Applies to GLASS “SOOT’S” UP AT You might also want to try a brand that is made from a different A VERY FAST RATE Only) type of wood (softwood vs. hardwood). Different woods have different characteristics when being burned. © 2021 United States Stove Company...
  • Page 25 Call 1-800-750-2723 Ext 5051 or Email to: parts@usstove.com IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ASHLEY PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM ASHLEY. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2021 United States Stove Company...
  • Page 26 WIRING DIAGRAM 7.5A 250V FUSE 1.25A 250V FUSE Ensure the wires are connected to the bottom two prongs of the hopper switch as shown. CORRECT WRONG © 2021 United States Stove Company...
  • Page 27 NOTES © 2021 United States Stove Company...
  • Page 28 Engineer Name: ____________________________________ Engineer Name: ____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: __________________________________________ Company: __________________________________________ Telephone No.: _____________________________________ Telephone No.: _____________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: ____________________________________ Items Replaced: ____________________________________ © 2021 United States Stove Company...