Télécharger Imprimer la page

Publicité

Liens rapides

• Please read this entire manual before installation and use
of this appliance. Failure to follow these instructions could
result in property damage, bodily injury, or even death.
• Contact your local building or fire officials about
obtaining permits, restrictions and installation inspection
requirements in your area.
• SAVE THESE INSTRUCTIONS. This manual will help you to
obtain efficient, dependable service from the heater,
and enable you to order repair parts correctly. Keep in a
safe place for future reference.
• If your heater is not properly installed, a house fire may
result. For everyone's safety, follow all Installation and
Operating Directions. Never use makeshift compromises
during the installation of this appliance. Contact your
local building or fire officials about restrictions and
installation inspection requirements in your area. These
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
Pellet Stove Room Heaters have been designed for use in
carbone, lesquels sont reconnus dans l'État de la Californie comme causant le cancer et
the US and Canada and are suitable for mobile homes.
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
renseignements, veuillez consulter le site www.P65warnings.ca.gov
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
MODEL: VG5501S
United States Stove Company
227 Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
Report #: F19-549
Certified to ASTM E1509-12 (2017) and
Certified to ULC S627-00-REV1
This unit is not intended to be used as a
primary source of heat.
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
ALL PICTURES SHOWN ARE FOR ILLUSTRATIVE
PURPOSES ONLY. ACTUAL PRODUCT MAY
VARY DUE TO PRODUCT ENHANCEMENT.
This manual is subject to change without
notice.
R
852718F-2301J

Publicité

loading

Sommaire des Matières pour United States Stove VG5501S

  • Page 1 This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov United States Stove Company 227 Industrial Park Rd., South Pittsburg, TN 37380 PH: (800) 750-2723 www.usstove.com...
  • Page 2 Safety Precautions • IMPORTANT: Read this entire manual before installing • Allow the stove to cool before performing any and operating this product. Failure to do so may maintenance or cleaning. Ashes must be disposed result in property damage, bodily injury, or even in a metal container with a tight fitting lid.
  • Page 3 Your stove is Certified to ASTM E1509-12 (2017)and Certified to ULC S627-00. This manual describes the installation and operation of the Vogelzang, VG5501S wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020.
  • Page 4 Installation INSTALLATION OPTIONS Read this entire manual before you install and use your pellet Side Wall to Stove stove. Failure to follow instructions may result in property Side Wall to Vent Pipe 11.5 damage, bodily injury, or even death! See specific installation details for clearances and other installation requirements.
  • Page 5 VENTING REQUIREMENTS • Install vent at clearances specified by the vent manufacturer. • Do not connect the pellet vent to a vent serving any other appliance or stove. • Do not install a flue damper in the exhaust venting system of this unit. The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes.
  • Page 6 VENT TERMINATION CLEARANCES A. Minimum 4-foot (1.22m) clearance below or beside any door or window that opens. B. Minimum 1-foot (0.3m) clearance above any door or window that opens. C. Minimum 3-foot (0.91m) clearance from any adjacent building. D. Minimum 7-foot (2.13m) clearance from any grade when adjacent to public walkways.
  • Page 7 ATTENTION: DO NOT vent under any porch, deck, awning, or in any semi enclosed or roofed area. Doing so may result in unpredictable airflow at the vent cap under certain conditions and can affect the performance of your stove, as well as, other unforeseeable issues. 69FAK OUTSIDE AIR SUPPLY (OPTIONAL, UNLESS INSTALLING IN A MOBILE HOME) Depending on your location and home construction, outside air may be necessary for optimal performance.
  • Page 8 Assembly Instructions Step 1 Step 2 Pull the factory installed wires out of the top of the Unpack the top mount controls and ensure that the stove. There will be two wire harnesses, as shown. wiring harness shown is attached securely. Step 3 Step 4 Connect the factory installed wiring harnesses to the...
  • Page 9 D. MODE (M/T) BUTTON • The Mode of the stove can be switched between manual and controlled with a Thermostat. Separate LEDs to the left of the two digit display indicate the mode of operation – Manual or T-Stat. The stove has to be in normal operation to be switched from Manual to T-Stat mode.
  • Page 10 PROPER FUEL THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY ! Factory-approved pellets are those 1/4” or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void all warranties.
  • Page 11 OPTIMAL OPERATION This pellet stove has been certified by the US EPA to meet strict 2020 guidelines. To Insure this unit produces the optimal minimal emissions, it is critical to follow the following guidelines.To achieve a “high burn” your stove should be set on setting 5 with the damper fully open.To achieve a “medium burn”...
  • Page 12 WARNING: FAILURE TO PROPERLY MAINTENANCE THE CLEAN OUTS WILL RESULT IN POOR PERFORMANCE OF THIS STOVE. INTERIOR CHAMBERS • Burn Pot: Periodically remove and clean the burn pot and the area inside the burn pot housing. In particular, it is advisable to clean out the holes in the burn pot to remove any build up that may prevent air from moving through the burn pot freely.
  • Page 13 Maintenance • Failure to clean and maintain this unit as indicated can result in poor performance, safety hazards, fire, and even death. • Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust system for any inspection, cleaning, or maintenance work.
  • Page 14 CHECK AND CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust (fines) that is building up in the feed system or pellets that are sticking to the hopper surface. Clean as needed. DOOR AND GLASS GASKETS Inspect the main door and glass window gaskets periodically.
  • Page 15 MAINTENANCE SCHEDULE Use the following as a guide under average use conditions. Gaskets around door and door glass should be inspected and repaired or replaced when necessary. Daily Weekly Monthly or as needed Burn Pot Stirred Empty Combustion Chamber Brushed Ashes Check Empty...
  • Page 16 Trouble Shooting Guide Display is Flashing “E2” Possible Causes Possible Remedies: (Unplug stove first when possible) Unhook air hose from the air switch and blow through it. Airflow switch hose or stove attachment pipes for If air flows freely, the hose and tube are fine. If air will not hose are blocked.
  • Page 17 Trouble Shooting Guide Display is Flashing “E3” Possible Causes Possible Remedies: (Unplug stove first when possible) The hopper is out of pellets Refill the hopper. The air dampener is too far open for a low feed If on the low setting, you may need to close the setting dampener all the way.
  • Page 18 Trouble Shooting Guide Display is Flashing “E4” Possible Causes Possible Remedies: (Unplug stove first when possible) The air inlet, burnpot, interior combustion air chambers, Follow all cleaning procedures in the maintenance combustion blower, or exhaust pipe are blocked with section of the owner’s manual. ash or foreign material.
  • Page 19 Trouble Shooting Guide Stove Feeds Pellets, But Will Not Ignite Possible Causes Possible Remedies: (Unplug stove first when possible) In some situations it may be necessary to have the damper completely closed for ignition to take place. Air damper open too far for ignition. After there is a flame, the damper can then be adjusted for the desired feed setting.
  • Page 20 Trouble Shooting Guide Stove Will Not Feed Pellets, But Fuel Feed Light Comes On As Designed Possible Causes Possible Remedies: (Unplug stove first when possible) Wait for the stove to cool for about 30 - 45 minutes. Locate the High Limit thermodisc and press the reset button on the back High limit switch has tripped or is defective.
  • Page 21 Trouble Shooting Guide Glass “Soot’s” Up At A Very Fast Rate Flame Is Lazy, Dark, And Has Black Tips After Stove Has Been On For A While, The Burnpot Overfills Possible Causes Possible Remedies: (Unplug stove first when possible) Stove or vent pipe is dirty, which restricts airflow through Follow all cleaning procedure in the maintenance the burnpot.
  • Page 22 Parts Diagram -22-...
  • Page 23 Parts List Part # Description 892199 Housing, PCBA Controller 80630 PCBA, Controller 891148 Lid Latch 892669 Top Weldment 80491 Lid Switch 80631 PCBA 892683 Side Panel, Right 892684 Side Panel, Left 892674 Vented Back Panel 892660 Hopper 80462 AC Electrical Connector 80602 Exhaust Blower 88166...
  • Page 24 Wiring Diagram -24-...
  • Page 25 Notes -25-...
  • Page 26 -26-...
  • Page 27 1. Le numéro de pièce __________________________________________________________________________ 2. La description de la pièce _____________________________________________________________________ 3. Le numéro de modèle ________________________________________________________________________ 4. Le numéro de série ___________________________________________________________________________ United States Stove Company 227 Industrial Park Rd., South Pittsburg, TN 37380 PH: (800) 750-2723 www.usstove.com...