Télécharger Imprimer la page

Publicité

Liens rapides

Owner's Instruction and Operation Manual
Model Number:
US5522
Report Number: F22-782
Certified to ASTM E1509-2022
and CAN/ULC S627:2023
Mobile Home / Transportable
Building Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
Save These Instructions In A Safe Place For Future Reference.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For
your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about
permits, restrictions and installation requirements in your area. NEVER OPERATE
THIS PRODUCT WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room
heater. Failure to follow instructions may result in property damage, bodily injury, or
even death. Improper Installation Will Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
© 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to
853929D-4903M
www.P65warnings.ca.gov
Ph. 800-750-2723

Publicité

loading

Sommaire des Matières pour United States Stove US5522

  • Page 1 State of California to cause cancer, birth defects, and/or other reproductive harm. For emissions standards. more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2024 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723...
  • Page 2 Your pellet stove has been safety tested and listed to ASTM E1509-12 (2017) and CAN/ULC S627:2023. This manual describes the installation and operation of the USSC US5522 pellet stove. This heater meets the 2020 U.S. Environmental Protection Agency’s emission limits for wood-heaters sold after May 15, 2020. Under specific EPA test conditions burning wood pellet fuel this heater has been shown to deliver heat at a rate of 13,640 to 32,591 Btu/hr.
  • Page 3 Declaration of Completion: As the qualified person responsible for the work described above, I confirm that the appliance as associated work has been installed as per manufacturer’s instructions and following any applicable building and installation codes. Signed: ______________________________________ Print Name: __________________________________Date: ______________ Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE © 2024 United States Stove Company...
  • Page 4 There will be two wire harnesses, as shown. 4. Secure the control panel to the top of the stove with two sheet metal screws. 2. Unpack the top mount controls and ensure that the wiring harness shown is attached securely. © 2024 United States Stove Company...
  • Page 5 2. Next slide the wood handle onto the door handle rod. 3. Slide the other provided washer onto the door handle rod. 4. Screw the provided nut onto the end of the door handle rod to secure everything in place. © 2024 United States Stove Company...
  • Page 6 CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE. Your heater should be installed by a qualified NFI (US) or WETT (Canada) technician. To find the nearest qualified installer, go to: https://nficertified.org, https://www.wettinc.ca/ © 2024 United States Stove Company...
  • Page 7 A Floor Protector of 1” (26 mm) thick is recommended for this installation. Canada - Floor protector must comply with CAN/ULC standards. Must extend 18” (458mm) past the front and 8” (203mm) beyond each side of unit. © 2024 United States Stove Company...
  • Page 8 Use the designated holes to secure the unit to the floor. venting installation of this unit. Purchase the appropriate appliance adapter from your preferred venting company prior to starting the ventilation process. Exhaust Pipe Fresh Air Intake © 2024 United States Stove Company...
  • Page 9 Take into account the chimney’s location to ensure it is not too close to neighbours or in a valley which may cause unhealthy or nuisance conditions. © 2024 United States Stove Company...
  • Page 10 7” (175 mm) diameter should consider a room that is centrally located within hole through the wall. your home. Choose a room that is large and open. It is © 2024 United States Stove Company...
  • Page 11 12ft complete the installation. A support bracket should be (3.7m), the pellet vent pipe size should be increased to placed just below the termination cap or one every 4ft 4” (102 mm) in diameter. © 2024 United States Stove Company...
  • Page 12 860001, 3-6” transition into 6” connector pipe (the illustration is only an example). Please conform to any local building codes or regulations having jurisdiction before you have a qualified installer proceed with this installation. © 2024 United States Stove Company...
  • Page 13 • The levels of heat output will incrementally change on • When room temperature drops below desired set-point the bar graph starting from heat range “1” to heat range the stove will ramp back up until it reaches the desired “5”. temperature. © 2024 United States Stove Company...
  • Page 14 Your pellet stove is designed to burn premium hardwood WHILE THE STOVE IS PLUGGED IN. pellets that comply with the Pellet Fuels Institute (PFI) standard (minimum of 40 lbs density per cubic ft, 1/4” to © 2024 United States Stove Company...
  • Page 15 If the stove shuts down push the “On/Off” button to re-start your stove. The stove will have to fully shut down and turn off before you will be able to restart the stove. © 2024 United States Stove Company...
  • Page 16 On other units the thermodisc has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that you call your dealer if © 2024 United States Stove Company...
  • Page 17 Over time ash or dust may accumulate on the blades of the circulation & exhaust fans. The fans should be inspected, periodically, and if any accumulation is present vacuumed clean as the ash or dust can impede © 2024 United States Stove Company...
  • Page 18 CO. the top as well as from the bottom. The creosote should be removed with a brush specifically designed for the © 2024 United States Stove Company...
  • Page 19 Gaskets Inspected 5. Re-install the retainer and eight nuts and rope gasket Glass Wiped Cleaned using high-temperature silicone to adhere the gasket Hopper (end of Empty & to the door. season) Vacuumed © 2024 United States Stove Company...
  • Page 20 (18 in) beyond the appliance on any side equipped with a door, and at least 200 mm (8 in) beyond the appliance on DO NOT INSTALL IN AN ALCOVE other sides, shall be protected by a continuous, durable, DO NOT INSTALL IN ANY FIREPLACE © 2024 United States Stove Company...
  • Page 21 If the other items check out OK, replace the high limit switch. ATTENTION: THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS IN THIS MANUAL. © 2024 United States Stove Company...
  • Page 22 (you may want to remove the hose entirely off the stove and the air switch first and make sure it is clear). If you hear a click, the air switch is working. BE CAREFUL TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH. © 2024 United States Stove Company...
  • Page 23 The control board is not sending power to the POF There should be a 5-volt (approximately) current going to the thermodisc or other auger system components. POF thermodisc after the stove has been on for 10 minutes. © 2024 United States Stove Company...
  • Page 24 If the sensor is not unplugged then turned on the sensor is damaged or has a short. If the sensor is damaged or has a short it will need to be replaced. © 2024 United States Stove Company...
  • Page 25 Circuit board malfunction. board is fine. If there is NOT power being sent to the blower when it shuts off during operation, then you have a bad control board. © 2024 United States Stove Company...
  • Page 26 If there is not a full current going to the auger motor when the fuel feed light is on, you have a bad control board. © 2024 United States Stove Company...
  • Page 27 You might also want to try a brand that is made from A VERY FAST RATE Only) a different type of wood (softwood vs. hardwood). Different woods have different characteristics when being burned. © 2024 United States Stove Company...
  • Page 28 WIRING DIAGRAM Ensure the wires are connected to the bottom two prongs of the hopper switch as shown. CORRECT WRONG © 2024 United States Stove Company...
  • Page 29 Email to: parts@usstove.com Distribution Blower 88106 Gasket IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING USSC PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM USSC. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 United States Stove Company...
  • Page 30 Engineer Name: ____________________________________ Engineer Name: ____________________________________ License No.: ________________________________________ License No.: ________________________________________ Company: __________________________________________ Company: __________________________________________ Telephone No.: _____________________________________ Telephone No.: _____________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: ____________________________________ Items Replaced: ____________________________________ © 2024 United States Stove Company...