MasterFlush 7600 Series Toilet
8. Install the floor mounting nuts and washers onto the
T-bolts.
9. Carefully torque the nuts to 30–40 in. lb (3.4–
4.5 N·m). When tight, the base should be securely
attached and flat against the floor.
10. Attach the bolt covers onto the nuts.
11. Reconnect the water supply line and torque the
connection to 30–40 in. lb (3.4–4.5 N·m).
12. Connect the electrical power to the toilet according
to the wiring diagram. See "Wiring Diagram" on
page 7.
13. Turn on the electrical power to the toilet.
14. Turn on the water supply to the toilet.
15. Flush the toilet several times and check for leaks.
e
8 Attaching the Cover
Pump/Base Cover
q
Locking Tabs
w
16. Attach the pump/base cover to the base using the
screws at the sides of the toilet base and using the
locking tabs at the sides and the back.
EN
w
q
Screws
e
6 .3 .2 Remote Installation
To install with a floor flange, return to "Floor Flange
I
Installation" on page 8.
Complete these steps to perform a remote toilet
installation.
1. Place the toilet in the location where it will be
installed.
2. Mark the fastener hole locations through the two
holes in the toilet base.
3. Drill pilot holes for the two hex screw fasteners
provided in the remote mounting hardware kit.
w
q
9 Removing the Black Elbow
Black Rubber Elbow
q
4. Remove the black rubber elbow from the check valve
at the back of the toilet.
Installation
Check Valve
w
9