Press and hold the Damp Signal and Wrinkle
Care buttons and then press the Power
button.
• This button sequence activates the
installation test. The code
the activation is successful.
3
Press the Start/Pause button.
• The appliance will start the test, which will
last a few minutes. The heat will be turned
on and the temperatures in the drum will be
measured.
4
Check the display for results.
• During the test cycle, monitor the Flow
TM
Sense
display on the control panel. If
Flow Sense indicator lights up when the
cycle ends, the exhaust system is adequate.
If the exhaust system is severely restricted,
the display will lights up. Have the system
checked immediately, as performance will
be poor. Other problems may also be
shown with error codes. Refer to the the
Error Code table for details and solutions.
5
End of cycle.
• At the end of the test cycle,
The test cycle will end and the appliance will
shut off automatically after a short delay.
Check the Duct Condition
TM
If the Flow Sense
LED is turned on, check the
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
• When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the results during the
two tests may not be the same.
• Do not interrupt the test cycle, as this could
result in inaccurate results.
• Even if the LED doesn't light up during the test
cycle, some restrictions may still be present in
the exhaust system. Refer to the Venting the
Error Codes
1Ns
will display if
Check the error code before you call for service.
ENd
will display.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Dryer section of this manual for complete
exhaust system and venting requirements.
Error
Possible Cause & Solution
Code
Temperature snesor failure.
tE1
or
tEz
• Turn off the appliance and call for
service.
Humidity sensor failure.
Hs
• Turn off the appliance and call for
service.
Ps
PF
Electric dryer power cord is not
,
,
connected correctly, or house power
NP
or
supply is incorrect.
• Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
• If the problem is a circuit overload,
have it corrected by a qualified
electrician.
GAs
Gas supply or service turned off. (Gas
Model only.)
• Confirm that house gas shutoff and
the dryer gas shutoff are both fully
open.
Excess or crushed
transition duct
INSTALLATION
25
Too many elbows or
exhaust too long