The machine must be tested and inspected at least once a year due to its use with hazardous materials. Worn parts must be
replaced. Never risk functionality and service life. Only use genuine parts.
Consumables
Description
Coupling socket
Coupling socket
Hose Ø=50
HEPA filter
Fine filter, polyester with integrated filter guard
Fine filter, cellulose with integrated filter guard
Plastic bag, 50 pcs
Intellibag, 10 pcs/roll
Plastic bag Longopac
For spare parts, see the
Dustcontrol
Warranty
The warranty period is two years and covers manufacturing defects. The warranty is valid on condition that the machine is used in
the normal way and receives the required service. Normal wear and tear is not covered. Repairs must be carried out by
Dustcontrol or personnnel authorized by Dustcontrol. Otherwise, the warranty is void.
Troubleshooting
Problem
Motor not running.
Motor stops immediately after
starting.
Motor runs, but no suction.
Motor runs, but poor suction.
Machine blows dust.
Abnormal sound from
machine.
EC Declaration of Conformity
We hereby declare that DC Tromb 400/a/c/L is in conformity with the following Directives and Standards: 2006/42/EC,
2014/35/EU, 2014/30/EU, EN 60204-1:2006/A1:2009, EN1822-1:A1:2009.
Part No.
2107
2129
2401
44016
44017
44043
4314
43619
432177
website.
Cause
Power supply not connected.
Incorrect fuse.
Suction hose not connected. Hose blocked.
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
Filter loose or damaged.
DC Tromb, Art.nr. 9480-H
Action
Connect power supply.
Replace with correct fuse.
Connect hose. Reverse or clean hose.
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Check and replace as necessary.
Book service.