Télécharger Imprimer la page

GHP Group TT360L Manuel D'utilisation Et De Fonctionnement page 14

Publicité

Les langues disponibles

Les langues disponibles

LIGHTING INSTRUCTIONS FOR PIEZO IGNITION MODELS (CONTINUED)
1. Stop! Read all safety information first.
2. Turn heater regulator knob counterclockwise
WARNING:
Stand to the side of unit while lighting. Do not stand or have any part of your body
over or near the heater while lighting.
3. Slowly open cylinder valve by turning counterclockwise
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP! Follow the safety information on the tag attached to the heater. If you do not smell gas, go to
the next step.
5. Turn heater regulator knob clockwise
(Fig. 3)
6. With safety shut-off valve plunger pressed in, immediately push down and release piezo ignitor button
repeatedly. This will light the burner. Mesh screen on burner glows red when lit.
7. Once the burner is lit, continue to depress the valve plunger for 30 seconds and then release.
Be careful not to shake the heater when releasing the plunger.
8. If burner does not light within 10 seconds, turn regulator knob to the (OFF) [
five(5) minutes for gas to dissipate before relighting. If burner goes out, repeat steps 5 through 7 or use a
match. If heater will not light after repeated attempts do not attempt to repair heater. Return heater to near
est authorized service center or to the address on the back of this manual, freight prepaid.
9. When burner is lit, turn heater regulator knob to desired heat setting (LOW) [ ], (MED) [
1. Tightly close propane tank valve by fully turning clockwise
2. Turn the heater regulator knob to the (OFF) [
before handling heater.
3. Always remove the heater from the propane tank after each use and store indoors. Do not store heater while
attached to propane tank. Do not store propane cylinders in a building, garage or any other enclosed area.
VENTILATION
Always be sure to supply proper ventilation while operating this heater.
Provide a minimum of 1.5 square feet (0.14m
PROPANE TANK TOP HEATER
to (LOW) [ ] position. Press in safety shut-off valve plunger.
TURNING OFF THE HEATER
to (OFF) [
] position.
.
.
] position. Wait at least 30 minutes for the heater to cool
) opening for fresh air supply.
2
13
] position. Wait at least
], or (HIGH) [
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
].

Publicité

loading