Check all gas connections with a 50/50 soap and water solution to be sure they are tight and leak proof.
The formation of bubbles indicate a gas leak. Correct all leaks before using the heater.
• The installation of your heater must meet all local codes and/or gas utility requirements or, in the absence of
local codes, with the Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural
and Propane Installation Code, CSA B149.1.
• The minimum clearances to combustible construction: Sides - 36" (91cm); Top - 48" (122cm);
Floor - combustible, must be maintained at all times. Not for use on finished floors.
• The hose assembly should be visually inspected prior to each use of the heater. If it is evident that there is
excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation.
• The replacement hose assembly shall be that specified by the manufacturer.
OPERATION - LIGHTING INSTRUCTIONS WHEN USING MATCH
Read and understand all safety information before operating heater.
WARNING:
Improper installation, alteration, service or maintenance can cause property
damage, injury or death.Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
WARNING:
Do not cover air inlet holes in mixing tube.
WARNING:
Make sure there is no open flame in the area.
Fully open the propane tank valve.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
PROPANE TANK TOP HEATER
CHECKING FOR LEAKS
WARNING:
Never use an open flame to check for leaks.