Maintenance And Cleaning - Oase FiltoClear 3000 Notice D'emploi

Masquer les pouces Voir aussi pour FiltoClear 3000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- English -
Operation
The unit is no longer biologically active at water temperatures below 50 °F (10 °C). Take the unit out of operation at water
temperatures below 46 °F (8 °C) or, at the latest, when freezing temperatures are to be expected.
Normal operating condition: The UVC unit is switched on. The UV-C lamp must be replaced after approx. 8000 operating
hours.

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries.
Protective measures: Switch off the mains voltage prior to carrying out work on the unit
Removing the UVC unit head
• Unplug UVC unit.
• Press the blue "Press" button (31) at the UVC unit head (4).
• Slightly turn the UVC unit head counter-clockwise.
• Carefully pull the UVC unit head out of the filter lid (8).
Inserting the UVC unit head
Note!
The O ring (32) on the closure of the UVC water housing
(4) is firmly clamped on. Only remove the O ring when it
must be replaced (e.g. when the O ring is porous).
• Carefully insert the UVC unit head (4) into the filter lid.
• Turn the UVC unit head clockwise up to the stop. The blue
"Press" button engages (31).
Opening the container
• Push back safety latch (36).
• Press the closing hook (35) inwards.
• Open and remove the clamping ring (10).
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Filtoclear 4000Filtoclear 8000

Table des Matières