Fitting the soiled water drain
The soiled water resulting from cleaning the unit can be used for fertilisation purposes. Recommendation: Connect and
route a drain hose (not included in our scope of delivery) up to a suitable point (e.g. plant bed)
• Unscrew the cover cap (9) from the soiled water drain socket (7).
• Push the union nut (26) over the transparent hose connector (20).
• Place the flow indicator flap (28) into the union nut.
• Screw tighten the hose connector to the socket using the union nut.
• Push the hose clamp (29) over the hose (30).
• Push the hose over the hose connector and secure with the hose
clamp. Leave the last segment free for use as a window to control
flow and soiling.
Closing the soiled water drain
Note!
During filter operation, ensure that the soiled water socket
(7) or a drain hose (30) connected to it is always closed
with a cover cap (9) with the flat sealing ring inserted. This
prevents unintended emptying of the pond.
• Push the hose clamp (29) over the hose (30).
• Push the hose connector (23) into the hose and
secure with the hose clamp.
• Close the hose connector using the cover cap with
the flat sealing ring (9) inserted.
Commissioning/Start-up
Attention! Sensitive electrical components.
Possible consequences: The unit will be destroyed.
Protective measures:Do not connect the unit to a dimmable power supply.
• Fit the connections (See Installation).
• Check the firm seating of hoses, cover cap for soiled water drain,
clamping ring with safety latch.
• Turn the function switch to water filtering (40), if it is not already
in this position.
• Switch on the pond pump.
• Only switch on the UVC unit when water is flowing through it.
You may have to wait for 24 hours. Connect power plug to the
socket. The UVC unit switches on immediately, the blue LED
(33) is lit.
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
33
40
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Filtoclear 4000Filtoclear 8000

Table des Matières