Standard
Hood Heights
Duct Cover
minimum ducted (A) 26-
"
1/2
minimum recirculating (B) 31"
maximum (C) 50"
Ceiling Heights
minimum ducted (D) 88-
" (7' 4-
1/2
minimum recirculating (E) 93" (7' 9")
maximum (F) 120" (10')
DUCTING
A minimum of 8" round duct is recommended to
Always use rigid type metal ducts only. Flexible
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 8" to 10".
If turns or transitions are required: Install as far
A
away from duct opening and as far apart between
n .
m i
B
n .
the two transitions as possible.
m i
x . C
m a
Minimum mount height between range top to hood
bottom should be no less than 26".
i n .
Maximum mount height should be no higher than
a x .
" m
2 6
" m
34".
3 4
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
mounted too high will be hard to reach and will
"
If available, also refer to range manufacturer's
height clearance requirements and recommended
Extension
Duct
Cover
41-
"
1/2
heights up to 12 feet. Turn to page 20 for part
46"
number and ordering information.
80"
DAMAGE-SHIPMENT / INSTALLATION:
") 103-
" (8' 7-
")
1/2
1/2
1/2
• Please fully inspect unit for damage before
108" (9')
installation.
150" (12' 6")
• If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
• If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
be made by arrangement between customer
and installer.
6
www.zephyronline.com