Télécharger Imprimer la page

Ariston 3319122 Instructions D'installation Et D'utilisation page 12

Kit gestion 2 zones sans fil

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
associating the wireless device
• Check that the connection between
the receiver and the heat genera-
tor has been completed successfully
(green led on) (Fig. 8) as instructed in
the receiver's instruction booklet.
• Check that the wireless 2 zone kit is
powered up (green led on) (Fig. 8)
• Hold the button on the wireless 2 zone
kit down for 3 seconds; the red led will
start flashing.
• Press the wireless 2 zone kit button
down again to associate the zones to
the outputs.
The red led will flash to indicate the as-
sociated zones:
1 flash every 2 seconds: zones 1 & 2
2 flashes every 2 seconds: zones 3 & 4
3 flashes every 2 seconds: zones 5 & 6
250ms
2s
DIAGNOSTICS
LED
STATUS
OFF
GREEN
ON
OFF
n -- flashes every 2 seconds
RED
Rapid flashing
ON
12 - GB
• Once the zones to be associated have
been selected, check the receiver
model and proceed as follows:
- Receiver (3319120):
press the button on the receiver for
5 seconds, the red LED emits 3 rapid
flashes in sequence and then turns off.
- Receiver (3319686):
set the microswitches as shown in fig-
ure 9 and press the button for 5s, the
red LED starts flashing.
At this point the association with the
device is started.
The association procedure now starts.
• If the procedure has terminated suc-
cessfully, the red led on the wireless 2
zone kit will go out.
Fig. 8
Zone 1&2
Zone 3&4
Zone 5&6
Fig. 9
DIAGNOSTICS
Controller not powered up or system reset
Controller powered up
Device associated
Zone selection
Cancel radio association
Device not associated
BUTTON
RED LED
ON
ON
ON
1
2
3
GREEN LED
ON
4

Publicité

loading