Introduction

RISCO Group's Dual Technology Grade 3 Industrial detector, WatchIN, is a unique detector with
signal processing based on two Passive Infrared (PIR) channels and two Microwave (MW)
channels. The detector can operate as a regular relay detector connected to any control panel, or
as a BUS accessory when connected to RISCO Group's ProSYS control panel via the RS485
BUS, thus having unique remote control and diagnostic capabilities.
The instructions describe herein, describe the WatchIN in Relay & BUS mode. For detailed
information regarding BUS mode installation, refer to BUS Mode installation chapter, page 16.

Mounting

Mounting Considerations

For optimum detection, select a location that is likely to intercept an intruder moving across
the coverage pattern at a 45° trajectory.
4

Relay Mode Installation

Typical Height: 2.4m (7'10")
Default Lens: Wide angle 25m (88') 90°
(RL325)
2.4m
(7'10")
WatchIN Detector -
Optional Installation
Height:
2.4m – 3.7m
(7'10"-12'2")
WatchIN Installation Manual
25m (88')