RISCO Group WatchIN RK325DT Guide D'installation page 19

Détecteur industriel à double technologie
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
Quick Keys
Parameter
possibility that the intruder will "Learn" the detector behavior.
[2][0][3][zzz]
3 LEDS
[1][3]
All 3 LEDs will operate.
[2][0][3][zzz]
Detection Sensitivity
[2]
Defines the sensitivity of the detector(MW + PIR)
[2][0][3][zzz]
Sensitivity Options
[2][1]..[4]
1) Low
2) Medium
[2][0][3][zzz]
MW Range
[3]
Defines the microwave channel range (maximum range - 27m)
[2][0][3][zzz]
MW Range options
[3][1]..[7]
1) Minimum
2) 20%
[2][0][3][zzz]
Alarm Logic
[4]
Determine the detector's logic of defining an alarm.
[2][0][3][zzz]
PIR and Microwave
[4][1]
Alarm is activated when both PIR and MW channels detect an alarm
(AND Logic)
[2][0][3][zzz]
PIR or Microwave
[4][2]
An alarm is activated when either PIR or MW channels detect an alarm (OR
Logic)
[2][0][3][zzz]
Lens Type
[5]
Defines the actual Lens of the detector
[2][0][3][zzz]
Lens Type Options
[5][1]..[2]
1) Wide Angle 2) Barrier
[2][0][3][zzz]
Anti-Mask
[6]
Defines the operation of Anti Masking detection
[2][0][3][zzz]
Anti-Mask Options
[6][1]..[2]
1) Disable 2) Enable (Default)
Quick Keys
Parameter
[2][0][3][zzz]
Arm/Disarm
[7]
Defines the operation of the LEDs and the anti masking detections while the
detector is armed
[2][0][3][zzz]
No
[7][1]
AM (Anti masking) is enabled
LEDs behave according to the LEDs parameter definition
[2][0][3][zzz]
Yes
[7][2]
AM (anti masking) is disabled
LEDs are disabled
[2][0][3][zzz]
Green line
[9]
The WatchIN includes a Green Line feature that follows environmental
guidelines by avoiding surplus emission.
[2][0][3][zzz]
NO
[9][1]
Green Line feature in disabled: MW is constantly activated
[2][0][3][zzz]
Yes
[9][2]
Green Line feature is enabled
[2][0][3][zzz]
SWAY
[0]
This option allows the recognition and immunity of swaing objects in a known
patern.
3) Normal
4) ACT (Anti-Cloak™ Technology)
3) 40%
5) 80%
4) 60%
6) Maximum
WatchIN Installation Manual
Default
Normal
Trimmer
7) Trimmer (MW is defined
by the trimmer setting on
the PCB)
PIR and Microwave
Wide Angle
Enable
Default
No
19

Publicité

Table des Matières
loading