Standard Swivel Installation; Wall Mounting - RISCO Group WatchIN RK325DT Guide D'installation

Détecteur industriel à double technologie
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61

Standard Swivel Installation

The WatchIN detector package contains a standard swivel for flexible installation. Please follow
the instructions below for mounting the detector with the Standard Swivel:
1. Open WatchIN front cover (Unlock C1, Figure1).
2. Release internal base (Unlock I1, Figure2).
3. Open knockouts on external base (Figure 7, Detail B)
W1: Wires knockout
S1,S2: Knockouts for securing external base to Standard Swivel
S3: External base locking screw knockout
4. On the swivel accessory remove the required swivel cable wiring knockout S2, S7 or S9
(Figure 7, Detail A).
5. Remove back tamper from the internal base (see "Changing Back Tamper Position"
paragraph) and connect it to S5 (Figure 7, Detail A) on the Standard Swivel.
Note:
Ensure that you see the engraved UP mark on the upper front face of the swivel.
6. Select the mounting installation type as follows:

Wall Mounting

a. Insert external cable wiring through knockouts S2, S7 or S9 and extract them (including the
tamper wires) through the Swivel Wires Passage (Figure 7, Detail B).
b. Secure swivel to the wall through holes S1, S3, S6 and S8.
CSMA
M1
M2
Tamper
Spring
M3
Holes
M4
c. Secure swivel to the wall through holes S1, S3, S6 and S8.
7. Insert tamper wires and external cable wiring from Standard Swivel through knockout W1 on
the external base (Figure 7, Detail B).
8. Connect the external base to the swivel using the dedicated snaps (Figure 8).
10
Detail A
Standard Swivel
S1 S2
Ø
mm
16
S9
S8
Ø
21 mm
Swivel Wires
Passage
WatchIN Installation Manual
S3
S1
S4
S5
S7 S6
Tamper
(see Detail C)
Figure 7
Detail B
Snaps
W1
S2
S3
Detail C

Publicité

Table des Matières
loading