7.4.

Returning to saved positions

Press the appropriate M1, M2 or M3 button and keep it depressed until
the desired position has been reached and the drives switch off.
DE
8.
Warning and error messages for eLevel /
eLevel+
Warnings and error messages can be shown at the manual switch
display.
These messages are generated by the control system and supply
information about malfunctions and their causes.
EN
Code
E 106
FR
E 212
F 215
IT
F 222
F 233
A 0
A 99
ES
A 100
20
Cause
Short circuit at the
manual switch port
Short circuit at the
Hall sensor
Short circuit at the
motor port
EEPROM read/write
error
MOSFET defective
SC reset OK
Overrun display
Enforced reset
Troubleshooting
The control system has detected a short
circuit at the manual switch port.
Operation of the control system will be
blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.
The control system has detected a short
circuit at the Hall sensor or at one or more
drives. Operation of the control system will
be blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.
The control system has detected a short
circuit at the power supply or at one or more
drives. Operation of the control system will
be blocked for approx. 10 seconds. Rectify the
fault. After this the control system must be
reinitialised.
System overload! Disconnect the device from
the mains. If the same error message is still
reported after 10 hours, contact your custom-
er service.
The control system must be reinitialised.