Télécharger Imprimer la page

ViewSonic CDM4300R Guide De L'utilisateur page 56

Publicité

Get function table:
Get Function
Length
Get-Contrast
8
Get-Brightness
8
Get-Sharpness
8
Get-Color
8
Get-Tint
8
Get-Volume
8
Get-Mute
8
Get-Input select
8
Get-Power
8
status : ON/
STBY
Get-Remote
8
control
Get-Power Lock
8
Get-Button Lock
8
Get-Menu Lock
8
Get-ACK
8
10.3.3. Remote Control Pass-through mode
When the PC sets the TV/DS to Remote Control Pass through mode, the TV/DS will send a 7-byte packet
(followed by "CR") in response to RCU button activation. Note, that in this mode the RCU shall have no
effect on the TV/DS function. For example: "Volume+" will not change the volume in the LCD but only sends
"Volume+" code to PC over the RS232 port.
IR Pass Through-Function format
Reply: (Command Type="p")
Name
Length
Byte Count
1 Byte
Bytes order
1
Example1: Remote Control pass-through when "VOL+" key is pressed for TV-05 Send (Hex Format)
Name
Length
Hex
0x36
ID
Command
Type
Code (ASCII)
g
a
g
b
g
c
g
d
g
e
g
f
g
g
g
j
g
l
g
n
g
o
g
p
g
q
g
z
ID
2 Byte
2~3
ID
0x30
0x35
Command
Code (Hex)
(Three ASCII bytes)
61
000 ~ 100
62
000 ~ 100
63
000 ~ 100
64
000 ~ 100
65
000 ~ 100
66
000 ~ 100
67
000: OFF (unmuted)
001: ON (muted)
6A
000~
6C
000: STBY
001: ON
6E
000 : Disable
001 : Enable
002 : Pass through
6F
000 : Unlock
001 : Lock
70
000 : Unlock
001 : Lock
71
000 : Unlock
001 : Lock
7A
000
Command
RCU Code1
Type
(MSB)
1 Byte
1 Byte
4
5
Command
Command
Type
0x70
0x31
47
Value Range
Comments
Gets Contrast value
Gets Brightness value
Gets Sharpness value
Gets Color value
Gets Tint value
Gets Volume value
Gets Mute ON/OFF
status
See Set-function table
This command is
used to test the
communication link.
RCU Code2
(LSB)
1 Byte
6
Value1
0x30
CR
1 Byte
7
CR
0x0D

Publicité

loading

Ce manuel est également adapté pour:

Cdm4900rCdm5500rVs16466Vs16467Vs16468