Télécharger Imprimer la page

DeWalt DXCM201 Guide D'utilisation page 26

Publicité

Les langues disponibles

Les langues disponibles

CODE
POSSIBLE CAUSE
1
Fittings are not tight.
2
Defective air tank.
3
Leaking seals.
4
Defective safety valve.
5
Prolonged excessive use of air.
6
Compressor is not large enough for accessory.
7
Hole in air hose.
8
Unit operating in damp or humid conditions.
9
Restricted air intake filter.
10
Loose belt.
11
Loose pulley.
12
Loose flywheel.
Carbon build-up in pump.
13
Troubleshooting Codes
POSSIBLE SOLUTION
Tighten fittings where air can be heard escaping. Check fittings
with soapy water solution. DO NOT OVERTIGHTEN.
Air tank must be replaced. Do not repair the leak.
WARNING: Risk of bursting. Do not drill into, weld or otherwise
modify air tank or it will weaken. The air tank can rupture or
explode.
Contact a D
service center.
Operate safety valve manually by pulling on ring. If valve still
leaks, it must be replaced.
Decrease amount of air usage.
Check the accessory air requirement. If it is higher than the SCFM
or pressure supplied by your air compressor, a larger compressor
is needed to operate accessory.
Check and replace air hose, if required.
Move unit to a dry, well ventilated area.
Clean or replace air intake filter.
Check belt tension, see Adjusting Belt Tension under
Maintenance.
Tighten pulley set screw, torque to 145-180 in.-lbs. (16.4–20.3 Nm).
Tighten flywheel screw, torque to 13–16 ft.-lbs. (17.6–21.7 Nm).
Contact a D
service center.
26
WALT factory service center or a D
e
WALT factory service center or a D
e
WALT authorized
e
WALT authorized
e

Publicité