9.3 REGULATIONS
Electromagnetic compatibility:
Directive 89/336/EEC
standard product
Device to be incorporated: tests carried out in accordance with the general rules:
•
Emission
•
Immunity
Low voltage:
Directive 73/23/EEC
standard product
Device to be incorporated designed in accordance with the standard
• EN 60730 as applicable
All the models must be VDE and ULapproved.
Other:
9.4 USER INTERFACE
The user interface is the front of the instrument, provided with
•
4 buttons
•
The 9 mm 3 digit display, for the symbolic or numeric display of the resources in question plus 8 LED icons
for visual indication of states or alarms.
The display shows chamber temperature, set point and/or times in cyclic mode depending on the operating
status.
Displaying and programming of the instrument through user interface was designed via navigation menu using
the buttons as described in section 9.2.
The buttons work with single pressing of the buttons
Provision
In this mode it is possible to directly set the cooking parameters and start the work cycle.
The parameters that can be set are essentially:
1. Cooking temperature
2. Cooking time
The oven start with the option of primarily setting temperature and cooking time.
Pressing the
"Start" button in cyclic mode enables the settings of the above parameters:
1. Cooking temperature
2. Cooking time
6. Start of chamber preheating cycle at the selected temperature.
7. Start immediate cooking.
EN 50081-1
EN 50082-1
RoHS 2002/95
21
and only for scrolling of label value and parameter values.