2
LED monitor defines corresponding functions and status
3
If the user switch off the units, fan motor keep running about another fours
minutes to decrease temperature of desiccant and heater after power off. End-
user shouldn't unplug the appliance until no air flow from the air outlet.
• Press MODE:
Select Quiet (L), normal dehumidification (M) and faster dry(H) and circulate above
functions.
1
Continuous appeared to set humidity ratio in the room
2
L (Quiet dehumidification) setting.
3
M (Normal dehumidification) setting.
4
H (Faster dry) setting. Under no circumstance, humidity ratio can be set on.
5
LED pilot lamp lighted on to respond functioning status.
• Press HUMID:
Setting room humidity ratio 40%~50%~60% and circulate L & M & continuous status.
1
When 40% is set: Humidistat detected room RH is lower < _ 38%, the unit
automatically turned itself off, the icon of dehumidification on LED goes off
50% & 60% setting are similar to above.
2
Continuous drain setting
Three LED light indication for easy observation of current humidity level:
Orange
Green
Red
• Press Swing:
Switching On or Off the swing function.
LED lights when turns on.
• Press ION:
Switching On or Off the ionizer.
LED lights when turns on.
• Press TIMER:
Setting operation time off by entering into 1/ 2 / 4/ 8 hours
PROTECTION OF WATER FULL
When condensed water is full, beeper will alarm 10 times. Meanwhile, the icon shown on
LCD monitor blinks, the unit stop operating automatically. The water reservoir must be
removed to empty and reinstalled before the rotary desiccant operates
Remove water reservoir in accordance
with arrow direction
4
32
32
LED light---20%RH-40%RH
LED light---41%RH-60%RH
LED light---61%RH-97%RH