TROUBLESHOOTING
Troubles
Possible Causes
The doors or windows are not closed.
There are heat sources inside the room.
The hot air exhaust hose is not connected
Not cool enough
or blocked.
Temperature setting is too high.
Air inlet / outlet is blocked.
The ground is not level or not flat
enough.
Noisy
The sound comes from the flowing of the
refrigerant inside the appliance.
Code "E2" on the
Room temperature sensor failed.
digital display
Code "E3" on the
Evaporator temperature sensor failed.
digital display
Code "E4" on the
Water-full warning
digital display
TECHNICAL DATA
Below data for your operating reference
Model
Rated voltage
Rated frequency
Rated input
Rated current
Cooling capacity
Moisture removal (L/H)
Air flow
ERP INFORMATION
Trademark
Model identification
Sound power (cooling)
Name of refrigerant
Rated power input for cooling (kW)
Rated energy efficiency ratio
GWP (kgCO
eq)
2
Energy efficiency class
Energy consumption for double ducts appliances
(kWh/h)
Energy consumption for single duct appliances
(kWh/h)
Power consumption in thermostat-off mode (W)
Power consumption in stand-by mode (W)
Cooling capacity
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP)
would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 3. This means that if 1 kg of this refrigerant
Solutions
Make sure all the windows and doors are
closed.
Remove the heat sources if possible.
Connect or clean the hot air exhaust hose.
Reset the temperature.
Clean the air inlet / outlet.
Place the appliance on a flat, level surface
if possible.
It is normal.
Replace the room temperature sensor.
Contact authorized service technician for
repair.
Replace evaporator temperature sensor.
Contact authorized service technician for
repair.
Drain out the water.
PAC-125152.3
220-240V
50Hz
950W
4.3A
9000BTU
1.0
300m³/h
Value
Emerio
PAC-125152.3
64.3dB(A)
R290
0.95
2.6
3
A
-
0.96
-
0.43
9000BTU
- 8 -