28. If the appliance is installed, operated or stored in an unventilated area, the room must be designed to
prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of
the refrigerant caused by electric heaters, stoves, or other sources of ignition.
29. The appliance must be stored in such a way as to prevent mechanical failure.
30. Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued
by an accredited organization that ensures competence in handling refrigerants according to a specific
evaluation recognized by associations in the industry.
31. Repairs must be performed based on the recommendation from the manufacturing company.
Maintenance and repairs that require the assistance of other qualified personnel must be performed
under the supervision of an individual specified in the use of flammable refrigerants.
32. Regarding the instructions for repairing appliances containing R290, please kindly refer to below
paragraphs.
33. Always let the appliance rest for at least 2 hours after moving it from one location to another.
Warning: Risk of fire / Flammable materials.
Read instruction manuals.
Operator's manual; operating instructions.
Service indicator; read technical manual.
Warning: Keep ventilation openings clear of obstruction.
Warning: The appliance shall be stored in a well-ventilated area where the room size corresponds to the room
area as specified for operation.
The required distance around the unit should be at least 30cm.
Appliance shall be installed, operated and stored in a room with a floor area larger than 7.9 m