5. Protections
: - a current protection circuit adjustable between
0 and 20 A.
- an over-voltage protection adjustable between
SEN
6. Ambient temperature
: Minimum
0 Set maximum
35 °C.
7. Cooling
: The instrument is cooled by forced air circulation
with a ventilator.
8. Mounting into а 19" rack
|
: The instrument is suitable for mounting in a 19" rack.
To this end, proceed as follows:
- Remove
side plates and top plate
(See under point A of chapter II).
- Remove feets and bottom plate.
- Replace plastic clamping plates A (see fig. 4) by
clamps provided on delivery.
9, Dimensions
- as table model
: Height
147 mm
Width
442 mm
Depth
400 mm
- when rack-mounted
: Height
133 mm
(without feet, but with mounting
Depth
400 mm
brackets)
10. Weight
See
SIE
SUP TP ROCE
DURE
A. ADJUSTING
TO THE LOCAL
MAINS VOLTAGE
As delivered the stabilizer is set for a 220 V mains voltage,
so that, if the local mains voltage is
110, 125 or 235 V, the stabilizer has to be adjusted to the correct value by changing the tappings on
transformer T26 (see Figs.
8 and 3).
To do this, one of the side panels must be removed first and then the top panel. The side panel is
removed by loosening its two screws to such a way that it can be slid off backwards
over the screw
heads (see Fig. 3).
Note: Make sure that the correct fuses (VL26 and VL27) have been inserted into the appropriate
holders (Fig. 3).
10 A delayed-action type for 220 V and 235 V.
20 A delayed-action type for 110 V and 125 V.
B.
CONNECTIONS.
1. Barth
The instrument can be earthed via:
S the earth screw " ©
"at the rear;
- the rim earth of the mains connector.
The circuit to be powered can be earthed via the earth terminal " Æ" at the front of the instrument
or the earth screw (terminal 2) on the 3-pole connecting block at the rear.
2. Mains