Installation Instructions - Dual Integrated Installation
STEP 1 REMOVE PACKAGING
(cont.)
Remove front access cover from unit by removing
two 1/4" hex head screws. Place the cover and
screws to the side for future
3/8" Drive
Screws
Shipping
Bracket
7/16" Drive
Screws
Remove two 3/8" drive screws and two 7/16" drive
screws from each side of the unit to release it from
the shipping skid. Tip the unit from the side enough
to remove the shipping material from under the unit,
but above the shipping skid (both sides)
CAREFULLY roll the unit off the back side of the
shipping skid.
Handle from side only with a hand truck.
STEP 2 INSTALL WATER LINE
WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
AVERTISSEMENT
alimentation d'eau potable seulement. Une alimentation
d'eau froide est requise pour faire fonctionner
la machine à glaçons et le pichet à remplissage
automatique. La pression d'eau doit se situer entre 40 et
120 psi. (275 à 827 kPa).
ADVERTENCIA
suministro de agua potable únicamente. Se requiere
un suministro de agua fría para el funcionamiento de
la máquina de hielos automática. La presión del agua
deberá estar entre 40 y 120 p.s.i. (275 – 827 kPa).
installation.
1/4" Hex Head
Screws
Raccordez l'appareil à une
Realice la conexión a un
STEP 2 INSTALL WATER LINE (cont.)
WARNING
Attach tubing clamp using existing hole only. DO
NOT drill into the refrigerator.
AVERTISSEMENT
Fixez le collier de serrage dans le trou présent seulement.
NE PERCEZ PAS dans le réfrigérateur.
ADVERTENCIA
Adhiera la abrazadera de la tubería usando el agujero
existente únicamente. NO perfore el refrigerador.
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line of
water.
the water valve and cold water pipe in a basement or
adjacent cabinet. The shut-off valve should be located
where it will be easily accessible.
Turn on the main water supply and flush debris. Run about
a quart of water through the tubing into a bucket. Shut off
water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are not recommended but
are included in many water supply kits. Before purchasing,
make sure a saddle type valve complies with your local
plumbing codes.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed plumber.
Route 1/4" OD copper or SmartConnect
plastic tubing between house cold water line and the water
connection location at the front of each unit.
™
SmartConnect
Refrigerator Tubing Kits are available.
One 8' (2.4m) water line (WX08X10006) is needed for
each unit. The waterline(s) will be taped to the floor using
masking tape after anti-tip bracket installation.
Tubing should be long enough to extend to the front of the
unit. Allow enough tubing to accommodate bend leading
into the water line connection.
NOTE: The only Café approved plastic tubing is supplied
™
in the SmartConnect
any other plastic water supply line because the line is under
pressure at all times. Other types of plastic may crack or
rupture with age and cause water damage to your home.
48
ELECTRIC SHOCK HAZARD
RISQUE DE DÉCHARGE
ÉLECTRIQUE
PELIGRO DE DESCARGA
ELÉCTRICA
a shut-off valve between
™
(WX08X10006)
Refrigerator Tubing kits. Do not use
31-1000731 Rev. 2