Very heavy product; hood handling and installation must be
carried out by at least two persons.
Expansion wall plugs are provided to secure the hood to most types
of walls/ceilings. However, a qualified technician must verify suitability
of the materials in accordance with the type of wall/ceiling. The
wall/ceiling must be strong enough to take the weight of the hood.
Do not tile, grout or silicone this appliance to the wall. Surface
mounting only.
Operation
This product is designed to work with an Elica remote control, either
supplied with the product or purchased separately as an optional.
To control the hood via remote control, the affiliation procedure must
be carried out.
CAUTION!
To begin, the hood must be disconnected and then reconnected to
the power supply and the affiliation procedure must be carried out
within the first minute of connection to the power.
Read the instructions supplied with the remote control, which provide
detailed instructions on affiliation and correct use.
Note: Using the remote control, delayed shut-down can be
programmed based on the aspiration speed (power) enabled at that
moment:
Speed 1 (low aspiration): 20 minutes
Speed 2 (medium aspiration): 15 minutes
Speed 3 (high aspiration): 10 minutes
T1. Suction speed (power) control key.
Press repeatedly until the desired speed is selected, choosing
between:
Speed OFF – LED L1: off
Speed 1 (low suction) – LED L1: green light
LED L2 turns green and flashes if the delayed hood
deactivation is enabled (only with remote control).
Speed 2 (medium suction) – LED L1: yellow light
LED L2 turns yellow and flashes if the delayed hood
deactivation is enabled (only with remote control).
Speed 3 (high suction) – LED L1: blue light
LED L2 turns blue and flashes if the delayed hood deactivation
is enabled (only with remote control).
Speed 4 (intensive suction) – LED L1: Blue button
Note 1: Speed 4 has a limited duration of 5 min., and then the
hood passes automatically to speed 2.
T2 Lighting control key (hob light - ambient light)
Press briefly for lighting the cooking hob
Press and hold longer to turn on and off and adjust the intensity
of ambient light
Note: ambient light is only available in some models.
Grease filter saturation warning - LED L1: red light
The warning is visible for about one minute after switching the hood
off.
When this warning appears the grease filter requires maintenance.
Charcoal filter saturation warning - LED L1: red light
The warning is available for about one minute after switching the
hood off.
When this warning appears the charcoal filter requires
maintenance.
Deactivation/activation of charcoal filter saturation
warning:
This warning is normally activated, to deactivate it:
Release both keys and press the same keys again, T1 and T2,