N
:
ETWORK CONNECTION
• An overvoltage category III Combined Circuit breaker and
Residual Current Device (RCD) with rated earth leakage
operation not exceeding 30mA must be fitted upstream on
the supply line in order to have a contact separation in all
poles that provide a full disconnection. The circuit breaker
must have a contact opening distance of at least 3 mm.
• The product is in class I and IP55, which is the protection
rate for the units to be used even outdoor. For keeping the
protection rate of the appliance, the connection of the
appliance with the power supply must be done by means
of a minimum IP55 system, as per the standards HD 384
CENELEC for Europe, or international IEC 60364-7 1988.
WARNING:
The radiator must never be installed in the upward or
inward position, the heating surface must always be
positioned so that the heat is directed downwards or
outwards.
The heater must never be installed in the upward or
inward position, the heating surface must always be
positioned so that the heat is directed downwards or
outwards.
Before being used, the heater must be
fixed to the wall or to the ceiling by means
of the provided supports.
.
.