Gas Supply
Installation of thisrange mustconformwith localcodesor,in the
absenceof localcodes,with the National FuelGas Code,ANSIZ223.1-
latestedition.In Canadathe rangemust beinstalledin accordance
with the currentCGAStandard CAN/CGA-B149 - InstallationCodesfor
GasBurning Appliances and Equipment a nd/orlocalcodes.
In TheCommonwealthOf Massachusetts
Thisproduct must be installedbya licensedplumberor gas fitter when
installedwithin the Commonwealthof Massachusetts. A "T" handle
typemanualgasvalve must be installedin the gas supplyline to this
appliance. A flexiblegasconnector, w hen used,must notexceeda
lengthof three(3) feet / 36 inches.
Gas leaks may occurin yoursystem and result in a dangerous
situation. Gasleaks may not be detectedby smell alone. Gas
suppliers recommendyou purchaseand install an ULapproved
gas detector. Install and use in accordancewith manufacturerls
instructions.
A QUALIFIED SERVICEMAN OR GAS APPLIANCE INSTALLER
MUST MAKE THE GAS SUPPLYCONNECTION.Leak testing of the
appliance shall be conducted by the installer according to the
instructions given in Step 6.
Apply a non-corrosive leak detection fluid to all joints and fittings in
the gas connection between the supply line shut-off valve and the
range. Include gas fittings and joints in the range if connections were
disturbed during installation. Checkfor leaks! Bubbles appearing
around fittings and connections will indicate a leak. If a leak appears,
turn off supply line gas shut-off valve, tighten connections, turn on the
supply line gas shut off valve, and retest for leaks.
CAUTION: NEVERCHECK FOR LEAKS WITH A FLAME. WHEN
LEAK CHECKIS COMPLETE,WIPE OFF ALL RESIDUE.
NATURAL GASSUPPLY LINEMUSTHAVE A NATURAL GASSERVICE
REGULATOR. INLETPRESSURE T OTHISAPPLIANCE SHOULD BE
REDUCED TOA MAXIMUMOF 14 INCHES WATER COLUMN (0.5 POUNDS
PERSQUARE INCH(P.S.I.) L IQUEFIED PETROLEUM (L.P.)/PROPANE GAS
SUPPLY LINEMUSTHAVE A L.P.GASPRESSURE REGULATOR. INLET
PRESSURE T OTHISAPPLIANCE SHOULD BEREDUCED TOA MAXIMUM
OF 14 INCHES WATER COLUMN (0.5 P.S.I.). I NLETPRESSURES I N
EXCESS OF 0.5 P.S.I.CANDAMAGE THEAPPLIANCE PRESSURE
REGULATOR AND OTHER GASCOMPONENTS IN THISAPPLIANCE AND
CANRESULT IN A GASLEAK.
Gassupply pressure for testing regulator must be at least 1" water
column pressure above manifold pressure shown on serial plate.
Check Pressure of House Piping System
1. Theapplianceand itsindividual shutoff valve must be
disconnected from the gassupply piping system duringany
pressure testingofthat system at testpressures in excess of
1/2 Ibs./sq.in.(3.5 kPa)(13.8 in. water column).
2. Theappliancemustbe isolatedfrom the gassupply piping
system by closingits individual m anualshutoff valve duringany
pressure testingofthe gas supply pipingsystem at test
pressures equal to or lessthan 1/2 Ibs./sq.in. (3.5 kPa)(13.8
in. water column).
A GASSHUT-OFF V ALVE SHOULDBEPUTIN ANACCESSIBLE LOCATION
INTHESUPPLY LINEAHEADOFTHE RANGE, F OR TURNING ONAND
TURNING OFFGASSUPPLY. Rangeis to be connected to house piping
with flexible metal connectors for gas appliances. CONNECTOR N UTS
MUSTNOTBE CONNECTED D IRECTLY T O PIPETHREADS. THE
CONNECTORS MUSTBEINSTALLED WITHADAPTORS PROVIDED WITH
THECONNECTOR.
The house piping and/or range connector used to connect the range to
the main gas supply must be clean, free of metal shavings, rust, dirt
and liquids (oil or water). Dirt, etc. in the supply lines can work its way
into the range manifold and in turn cause failure of the gas valves or
controls and clog burners and/or pilot orifices.
Always use a new flexible connector.Do not use exsisting flexible
connector.
NOTE: I t is recommendedto use a CSAcertified flexible connectorno longerthan 36" (91.4 cm) with a minimum BTU/HRrating of 88,200.
'If!
I
"
v IV
"*,_
I"
"!
_1
Follow these procedures to remove appliance for servicing:
1. Slide rangeforward to disengagerangefrom the anti-tip bracket.
2. Shut off gassupply to appliance.
3. Disconnect e lectricalsupply to appliance, i f equipped.
4. Disconnect g as supply tubingto appliance.
5. Reverseprocedure to reinstall. If gas line has beendisconnected,
THE APPLIANCE
checkfor gas leaks after reconnection.
6. To prevent range from accidentally tipping,range mustbe securedto the floor by sliding rear levelinglegintothe anti-tip bracket.
NOTE: A qualified servicer should disconnect and reconnect the gas supply. Theservicer MUSTfollow installation instructions provided with the gas
appliance connector and the warning label attached to the connector.
Whenyour range requires service or replacement parts, contact your dealer or authorized service agency.Pleasegive the complete model and serial
number of the range which is located on flip-up plate at the rear of upper left-hand corner or center of backguard.
I Your range may not be equipped with some of the features referred to in this manual.