WARNING
CAUTION
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a
minimum height of 5 feet (1.52 m) where small
children cannot reach, away from moving parts of
door and door hardware. If installing into drywall, drill
5/32" holes and use the anchors provided. For pre-
wired installations (as in new home construction), it
may be mounted to a single gang box (Figure 2).
1. Strip 7/16" (11 mm) of insulation from one end of
bell wire and connect to the two screw terminals
on back of door control by color: white wire to 2
and white/red wire to the 1.
2. Console Model: Remove white cover by gently
prying at slot in top of the cover with a small flat
head screwdriver. Fasten with 6AB x 1-1/4"self-
tapping screws (drywall installation) or 6-32 x 1"
machine screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" (3 mm) to
protrude above wall surface.
• Position bottom of door control on screw head
and slide down to secure. Adjust screw for snug
fit.
• Drill and install top screw with care to avoid
cracking plastic housing. Do not over tighten.
• Insert top tabs and snap on cover. (To remove
cover after mounting, gently pry at top with paper
clip or small flat head screwdriver.)
3. (For standard installation only) Run bell wire up
wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell
wire. Connect bell wire to the quick-connect
terminals as follows: white to white and white/red
to red.
NOTE: When connecting multiple door controls to
the opener, twist same color wires together. Insert
wires into quick-connect holes: white to white and
red/white to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach
entrapment warning label to wall near door
control, and manual release/safety reverse test
label in a prominent location on inside of garage
door.
NOTE: DO NOT connect power and operate
opener at this time. The trolley will travel to the full
open position but will not return to the close
position until the sensor beam is connected and
properly aligned.
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet
(1.52 m) and away from all moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of closing
garage door.
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white;
white/red to red.
HARDWARE SHOWN ACTUAL SIZE
6AB x 1-1/4" Screw
Control Console (std installation)
6-32 x 1" Screw
Control Console (pre-wired)
Figure 1
REMOVE & REPLACE COVER
To Replace,
Insert Top
Tabs First
PREMIUM
Lighted
CONTROL CONSOLE
Push Button
Top
Mounting
Hole
WHITE
Terminal
2
Screws
RED
Bottom
1
Bell
Mounting
Wire
Hole
(BACK VIEW)
Door Control
Connections
Strip wire 7/16" (11 mm)
7/16"
18
WARNING
WARNING
Insulated
Staples
Dry Wall Anchors
Figure 2
PRE-WIRED
INSTALLATION
To Remove,
Twist
Here
Quick-Connect
Terminals
2-Conductor
Bell Wire
Light
Lock
To release wire, push in
tab with screwdriver tip
Red
White
Grey
24 Volt
2-Conductor
Bell Wire in
Gang Box
Antenna