en - Technical details
Electrical version and electrical data
Connection voltage
Frequency
Total amps.
Max. fuse (time delay fuse)
Mimimum circuit ampacity
Water connection
Cold water connection
Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose supplied
Hot water connection
Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied
Hot water connection (for variants without heating or with reduced heater rating)
Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied
Hard water connection (optional)
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied
Drainage
Maximum drain water temperature
Waste water connection (on machine)
Drain (on site)
Maximum drainage rate
Connection for equipotential bonding
Male thread
Toothed washers
20
208/240 V 3 Ph
3 X 24.6 A
3 X 24.6 A
1.45-145 psi (100-1000 kPa/1-10 bar)
31.5 l/min
3 x 61" (1.55 m)
158 °F (70 °C)
1.45-145 psi (100-1000 kPa/1-10 bar)
61" (1.55 m)
194 °F (90 °C)
1.45-145 psi (100-1000 kPa/1-10 bar)
61" (1.55 m)
1.45-145 psi (100-1000 kPa/1-10 bar)
2 x 61" (1.55 m)
203°F (95°C)
Plastic pipe HT DN 70
Connection DN 70
200 l/min
60 Hz
3 X 25 A
3 x 3/4"
16 l/min
1 x 3/4"
16 l/min
1 x 1"
32 l/min
2 x 3/4"
M10
M10