2.5
General Specification
Table 2.8:Environmental and Electrical Specifications
Description
Programming Method
Program Capacity
Program Storage
Device Backup
RTC Backup
RTC Accuracy
Operating Temperature
Storage Temperature
Vibration Resistance - Direct
Mounting
Vibration Resistance - DIN Rail
mounting
Shock Resistance
Noise Immunity
Humidity
Dielectric withstand voltage
Function Block
64 Function Blocks or 1500 bytes
Built in EEPROM (no battery backup required) or optional EEPROM cassette
20 Days at 25°C (by capacitor)
20 Days at 25°C (by capacitor)
5 seconds / day
0 - 55 °C
(-30) - 70 °C
Conforms to IEC 68-2-6; 10-57 Hz: 0.15 mm Constant Amplitude
57-150 Hz: 19.6 m/s
Sweep Count for X,Y,Z: 10 times (80 minutes in each direction)
Conforms to IEC 68-2-6; 10-57 Hz: 0.075 mm Constant Amplitude
57-150 Hz: 9.8 m/s
Sweep Count for X,Y,Z: 10 times (80 minutes in each direction)
Conforms to IEC 68-2-27: 147m/s
3 times in each direction X,Y, and Z
1000Vpp, 1 microsecond, 30 - 100 Hz, tested by noise simulator
35 - 85% Relative Humidity, no condensation
3750V AC > 1 min per EN60730-1 between the following points:
Power/Input Terminals and Relay Output Terminals
Relay Output Terminal and Relay Output Terminal
All Terminals and the DIN 43880 Control box or equivalent
Hardware Specification 2
Specification
2
Acceleration
2
Acceleration
2
Acceleration, Action Time: 11 ms