TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult your
dealer or the HiKOKI Authorized Service Center.
1. Power tool
Symptom
Tool doesn't run
Tool suddenly stopped
Battery cannot be installed
2. Charger
Symptom
The charge indicator lamp
rapidly fl ickers purple, and
battery charging doesn't
begin.
The charge indicator lamp
blinks red, and battery
charging doesn't begin.
Battery usage time is short
even though the battery is
fully charged.
The battery takes a long
time to charge.
The USB power lamp
has switched off and the
USB device has stopped
charging.
USB power lamp does not
switch off even though the
USB device has fi nished
charging.
It is unclear what the
charging status of a USB
device is, or whether its
charging is complete.
Possible cause
No remaining battery power
The battery is overheated.
Attempting to install a battery other than
that specifi ed for the tool.
Possible cause
The battery is not inserted all the way.
There is foreign matter in the battery
terminal or where the battery is attached.
The battery is not inserted all the way.
The battery is overheated.
The battery's life is depleted.
The temperature of the battery, the charger,
or the surrounding environment is extremely
low.
The charger's vents are blocked, causing its
internal components to overheat.
The cooling fan is not running.
The battery's capacity has become low.
The USB power lamp lights up green to
indicate that USB charging is possible.
The USB power lamp does not switch off
even when charging is complete.
Charge the battery.
Let the battery cool down.
Please install batteries that are multi volt or
BSL18xx series.
Insert the battery fi rmly.
Remove the foreign matter.
Insert the battery fi rmly.
If left alone, the battery will automatically
begin charging if its temperature decreases,
but this may reduce battery life. It is
recommended that the battery be cooled in
a well-ventilated location away from direct
sunlight before charging it.
Replace the battery with a new one.
Charge the battery indoors or in another
warmer environment.
Avoid blocking the vents.
Contact a HiKOKI Authorized Service
Center for repairs.
Replace the battery with one that has
capacity remaining.
Plug the charger's power plug into an
electric socket.
This is not a malfunction.
Examine the USB device that is charging to
confi rm its charging status.