Les langues disponibles

Battery
performance
dropped
significantly.
Shaving
performance
dropped
significantly.
Shaver head is
damp.
CLEAN&CHARGE STATION
Cleaning does
not start when
pressing the
start button.
Increased
consumption of
cleaning fluid.
14
1. Foil and cutter are
worn which requires
more power for each
shave.
2. Shaver head is
regularly cleaned
with water but not
lubricated.
1. Foil and cutter are
worn.
2. Shaving system is
clogged.
1. Drying time after
automatic cleaning
was too short.
2. Drain of the
Clean&Charge Station
is clogged.
1. Shaver is not placed
properly in the
Clean&Charge Station.
2. Cleaning cartridge
contains not enough
cleaning fluid (display
blinks red).
Drain of the Clean&Charge
Station is clogged.
1. Renew Foil & Cutter cassette.
2. If the shaver is regularly cleaned with
water, apply a drop of light machine oil
on top of the foil once a week for
lubrication.
1. Renew Foil & Cutter cassette.
2. Soak the Foil & Cutter cassette into hot
water with a drop of dish liquid.
Afterwards rinse it properly and tap it
out. Once dry apply a drop of light
machine oil on the foil.
1. Clean directly after shaving to allow
enough time for drying.
2. Clean the drain with a wooden
toothpick.
1. Insert shaver into the Clean&Charge
Station and push it to the rear side of
the station (contacts of the shaver
need to align with contacts in the
station).
2. Insert new cleaning cartridge.
Press start button again.
– Clean the drain with a wooden
toothpick.
– Regularly wipe the tub clean.