Télécharger Imprimer la page

IPC 3160T Manuel D'instructions page 26

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
Before carrying out any operations, disconnect the cleaner from the power
(via the omnipolar switch or by unplugging the plug from the socket) and water supply.
FAULTS
When the switch is turned the cleaner
does not start.
No jet delivered.
The pump turns but does not reach the
rated pressure.
When the lance is turned on the pres-
sure falls and rises.
Insufficient detergent suction.
Presence of water in oil.
Water leaks from head.
For maintenance and/or repairs, use only original spare parts which offer the greatest characteristics of quality and
reliability. Failure to use original spare parts frees the manufacturer from all responsibility.
English
TROUBLE-SHOOTING
CAUSES
Faulty electric connection.
Thermal protection has tripped.
The omnipolar switch has tripped.
Faulty water circuit connection.
Clogged water filter.
Mains tap turned off.
Water intake filter blocked.
Faulty water circuit connection.
Pressure regulation valve is set at
minimum.
Lance nozzle is worn.
Detergent intake device on the lance is
turned on. (DS Vers.)
Dirty or worn valves.
The nozzle is clogged or deformed.
Insufficient supply.
No detergent in the tank.
Control on the lance not switched on.
Oil seal rings worn.
Gaskets worn.
IMPORTANT:
- 26 -
REMEDIES
Check the mains voltage.
Reset (if it trips again, apply to the
technical service centre).
Reset (if it trips again, apply to the
technical service centre).
Check it.
Clean it.
Turn it on.
Clean it.
Check it.
Regulate it.
Apply to our technical service centre.
Turn it off.
Apply to our technical service centre.
Clean or consult our technical service
centre.
Check it.
Fill the detergent tank.
Set the control on the lance.
Apply to our technical service centre.
Apply to our technical service centre.

Publicité

loading

Ce manuel est également adapté pour:

N. royal jet3175tDs 3160tDs 3175t