Pneumatic Connection; Position Of Potentiometers And Jumpers - Asco JOUCOMATIC SENTRONIC 601 Série Manuel D'installation

Servodistributeurs à commande analogique pour application sur le vide
Masquer les pouces Voir aussi pour JOUCOMATIC SENTRONIC 601 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB

POSITION OF POTENTIOMETERS AND JUMPERS

Remove the lid of the body by unscrewing the 4 screws, taking care not to loosen or damage the cable
connections, and adjust the potentiometer.
OBSERVE PRECAUTIONS
E S D

PNEUMATIC CONNECTION

Connecting the pneumatic ports as illustrated below.
Each screw connection is lined with a close-fitting synthetic sealing disc. PTFE (polytetrafluoroethylene) sealing
tape and hemp should not be used as they may get inside the valve and damage it. Use an appropriate silencer
at port (3). The diameter of the pneumatic lines must be adjusted to the nominal diameter of the valve. The
diameter of output line (2) must be larger or equal to that of input line (1).
CUT-OFF VERSION
VACUUM
PUMP
atmosphere
24
SENTRONIC G 1/8, G 1/4, G 1/2, G 1
P1
= Span adjustment
P2
= Offset adjustment
P4-P5 = Gauging of vacuum sensor: DO NOT MODIFY THIS ADJUSTMENT
P6
= Pressure switch adjustment (window size)
P7
= Proportional gain (1. . .11)
WARNING
FOR HANDLING
ELECTROSTATIC
DISCHARGE
SENSITIVE DEVICES
OUTLET
3
2
1
This product contains electronic components sensitive to
electrostatic discharge. If a person or an object comes in contact
with the electrical components of the product, there will be an
electrostatic charge which can damage or destroy the product.
To reduce the risk of electrostatic discharge, please observe the
handling precautions and recommendations contained in standard
EN100 015-1 at all times. Do not connect or disconnect this device
when it is energised.
VACUUM
PUMP
Coil
BY-PASS VERSION
3
2
1
atmosphere
P5
P2
P4
P1
P7
P6
max.
OUTLET

Publicité

Chapitres

Table des Matières
loading

Table des Matières