All manuals and user guides at all-guides.com Servodistributeurs série 601 à commande digitale Servo-valves series 601 with digital control SENTRONIC Manuel d'installation Installation manual MS-P300-12.R1a (383 45 64)
All manuals and user guides at all-guides.com SOMMAIRE Raccordement électrique du connecteur Raccordement pneumatique Fonction mémoire et RaZ pression Modification décalage du zéro Modification de la pente Gain proportionnel Pressostat (option et réglage) 08 - 09 Option retour electrique externe Encombrements et masses 10 - 11 Position des potentiomètres...
All manuals and user guides at all-guides.com RACCORDEMENT DU CONNECTEUR SUR SENTRONIC A COMMANDE DIGITALE G 1/8 (Ø 3 mm) - G 1/4 (Ø 6 mm) - G 1/2 (Ø 12 mm) - G1 (Ø 20 mm) avec fonction mémoire 010 537 avec fonction RAZ pression 010 606 Vu côté...
All manuals and user guides at all-guides.com FONCTION MEMOIRE ET RaZ PRESSION FONCTIONNEMENT L'alimentation principale de la vanne 24 V DC ±10 % doit être stabilisée avec un taux d'ondulation maxi de 10% Définition des niveaux logiques. niveau bas (niveau logique 0) : 0..6 V (doit être compris entre 0 et 6V) niveau haut (niveau logique 1) : 8..24 V (doit être compris entre 8 et 24V)
Page 5
All manuals and user guides at all-guides.com FONCTION MEMOIRE (option 010 537) La fonction mémoire permet de mémoriser une consigne dans la Sentronic et de maintenir la pression correspondant en sortie de l'orifice 2. Toutes les autres combinaisons de bits se présentant en entrée de la vanne sont ignorées tant que la borne L est maintenue à...
Page 6
All manuals and user guides at all-guides.com FONCTION R A Z PRESSION (option 010 606) La fonction RAZ pression maintient la pression de sortie à 0 bar, tant que la borne L reste à un niveau logique 0. Aussi longtemps que la borne L (RAZ pression) est maintenue à un niveau logique 0 la pression de sortie de la vanne reste à...
All manuals and user guides at all-guides.com REGLAGES Les servodistributeurs Sentronic à commande digitale sont réglés en usine pour avoir : - Le zéro de pression pour une combinaison de bits nulle (0000 0000). - La pression maximale de régulation (PMR) pour la combinaison digitale (1111 1111). - Une hystérésis minimum.
All manuals and user guides at all-guides.com GAIN PROPORTIONNEL : On peut ajuster le gain dans une plage de réglage de 1 à 11 avec le potentiomètre P7. Le gain proportionnel est régler, en usine, au maximum (11). On peut adapter le gain proportionnel pour réduire l'oscillation et les dépassements (over shoot). Pour augmenter le gain, il faut tourner P7 dans le sens horaire.
All manuals and user guides at all-guides.com REGLAGE DU PRESSOSTAT 1 - Raccordez la Sentronic suivant le schéma en page 03. Ne pas appliquer de pression en entrée de la vanne. 2 - Mise à zéro du potentiomètre P6, en tournant dans le sens horaire (pas de butée franche, on entend un clic de fin de course).
All manuals and user guides at all-guides.com ENCOMBREMENTS ET MASSES G 1/8 Masse : 0,650 Kg Vue de dessous ØM4 2 Ø M4 G 1/8" G 1/4 à G 1 ØM4 • Fixation arrière : 2 trous taraudés Ø G prof. S •...
All manuals and user guides at all-guides.com ENCOMBREMENTS ET MASSES VERSION AVEC ALIMENTATION EXTERNE DU CAPTEUR DE PRESSION G 1/8 Vue de dessous Masse : 0,730 Kg ØM4 2 Ø M4 G 1/8 (alimentation extérieure G 1/8" du capteur de pression) G 1/4 à...
All manuals and user guides at all-guides.com POSITION DES POTENTIOMETRES ET JUMPERS Oter le couvercle du boitier en dévissant les 4 vis. Attention de ne pas desserrer ou d'endommager les connexions internes, puis intervenir sur le(s) potentiomètre(s) de réglage. SENTRONIC G 1/8, G 1/4, G 1/2, G 1 Bobine max.
Page 13
All manuals and user guides at all-guides.com Servo-valves series 601 with digital control SENTRONIC Installation manual MS-P300-12.R1a...
Page 14
All manuals and user guides at all-guides.com SUMMARY Electrical connection Pneumatic connection Memory and reset function Offset adjustment Span adjustment Proportional gain Pressure switch (option and adjustment) 20 - 21 Option external feedback value input Dimensions and weights 22 - 23 Position of potentiometers and jumpers This product complies with the essential requirements of the EMC-Directive 89/336/EEC and amendments.
Page 15
All manuals and user guides at all-guides.com WIRING CONNECTOR ON SENTRONIC WITH DIGITAL CONTROL G 1/8 (Ø 3 mm) - G 1/4 (Ø 6 mm) - G 1/2 (Ø 12 mm) - G1 (Ø 20 mm) with memory function 010 537 with zero switch 010 606 View on the soldered wires side of female...
All manuals and user guides at all-guides.com MEMORY AND RESET FUNCTION OPERATING PRINCIPLE Valve supply voltage is always stabilized 24 V DC ±10 % with a maximum ripple factor of 10 %. Definition of logic values: low value (logic 0) : 0..6 V (must stay between 0 to 6 volts) high value (logic1) : 8..24 V (must stay between 8 to 24 volts)
Page 17
All manuals and user guides at all-guides.com MEMORY FUNCTION (option 010 537) The Memory Function enables the Sentronic to keep a setting and to hold the corresponding pressure in the output of port 2. All other bit combinations presented are ignored as long as Pin L is held in Logic value 1 (memory). When Pin L is in Logic value 0, the valve considers all variations of bit combinations which are presented at the valve digital input.
Page 18
All manuals and user guides at all-guides.com RESET FUNCTION (option 010 606) The RESET function helds output pressure at 0 bar, as long as pin L stays in logic value 0. As long as pin L (ENABLE) is maintain at logic value 0, the valve output pressure remains at 0 bar. All bit combination settings at the input are ignored and the valve remains at 0 bar.
All manuals and user guides at all-guides.com DIGITAL CONTROL Digital control servo-valves are factory set for : - pressure zero for null bit combination (0000 0000). - maximum output pressure (PMR) for digital setting (1111 1111). - minimum hysteresis. - maximum proportional gain. Customer adjustment can be done for offset and span.
All manuals and user guides at all-guides.com PROPORTIONAL GAIN : You can use gain adjustment in a range from 1 to 11with potentiometer P7. Proportional gain is factory adjusted to maximum (11). You can use proportional gain to reduce oscillation and overshoot. To increase the gain, turn P7 clockwise.
All manuals and user guides at all-guides.com PRESSURE SWITCH ADJUSTMENT 1 - Connect the Sentronic connector according to page 13 Do not apply pressure to the input port. 2 - Turn P6 potentiometer clockwise to the maximum. 3 - Connect a LED with resistor 4,7 KΩ between pin M and pin B or pin M and pin A according to the pressure switch option.
All manuals and user guides at all-guides.com DIMENSIONS AND WEIGHTS G 1/8 Weight : 0,650 Kg View from below ØM4 2 Ø M4 G 1/8" G 1/4 to G 1 ØM4 • Rear mounting by 2 tapped holes Ø G depth.
Page 23
All manuals and user guides at all-guides.com DIMENSIONS AND WEIGHTS VERSION WITH EXTERNAL PRESSURE PORT FOR THE SENSOR G 1/8 View from below Weight : 0,730 Kg ØM4 2 Ø M4 G 1/8 (pressure sensor G 1/8" external input) G 1/4 to G 1 ØM4 •...
All manuals and user guides at all-guides.com POSITION OF POTENTIOMETERS AND JUMPERS Remove the lid of the body by unscrewing the 4 screws. Caution : do not loosen or damage the cable connections, and adjust the potentiometer. SENTRONIC G 1/8, G 1/4, G 1/2, G 1 Coil max.