Télécharger Imprimer la page

Zanussi ZGG62414BA Notice D'utilisation page 26

Publicité

Les langues disponibles

Les langues disponibles

A
B C
A. End of shaft with nut
B. Washer supplied with the appliance
C. Elbow supplied with the appliance
Liquid gas
Use the rubber pipe holder for liquid gas. Always
engage the gasket. Then continue with the gas
connection.
The flexible pipe is prepared for apply when:
it can not get hot more than room temperature,
higher than 30°C;
it is no longer than 1500 mm;
it shows no throttles;
it is not subject to traction or torsion;
it does not get in touch with cutting edges or
corners;
it can be easily examined in order to make sure
its condition.
The control of preservation of the flexible pipe
consists in checking that:
it does not show cracks, cuts, marks of burnings
on the two ends and on its full length;
the material is not hardened, but shows its
correct elasticity;
the fastening clamps are not rusted;
expired term is not due.
If one or more defects are visible, do not repair the
pipe, but replace it.
WARNING! When installation is
complete, make sure that the seal of
each pipe fitting is correct. Use a
soapy solution, not a flame!
INJECTORS REPLACEMENT (ONLY FOR
BELGIUM)
1. Remove the pan supports.
2. Remove the caps and crowns of the burner.
3. With a socket spanner 7 remove the injectors
and replace them with the ones which are
necessary for the type of gas you use (see
table in "Technical Data" chapter).
4. Assemble the parts, follow the same procedure
backwards.
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type of
26
gas supply. You can find this plate in the
package supplied with the appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you must fit
an applicable pressure adjuster on the gas supply
pipe.
ADJUSTMENT OF MINIMUM LEVEL (ONLY
FOR BELGIUM)
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob .
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
5. If you change:
from natural gas G20/G25 20/25 mbar to
liquid gas, fully tighten the bypass screw in.
from liquid gas to natural gas G20/G25
20/25 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
Make sure that the rated voltage and type of
power on the rating plate agree with the voltage
and the power of the local power supply.
This appliance is supplied with a mains cable. It
has to be supplied with a correct plug which
can hold the load that the rating plate rates.
Make sure that you install the plug in a correct
socket.
Always use a correctly installed shockproof
socket.
Make sure that there is an access to the mains
plug after the installation.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the

Publicité

loading

Ce manuel est également adapté pour:

Zgg62414waZgg62414xa