Télécharger Imprimer la page

Eurocave Inoa 25 Mode D'emploi page 22

Climatiseurs de cave
Masquer les pouces Voir aussi pour Inoa 25:

Publicité

Les langues disponibles

Les langues disponibles

7/ COMMISSIONING YOUR CONDITIONER
VII. Heating function
The EuroCave INOA conditioner has a heater (650 W) allowing the internal temperature in your cellar to be maintained
at an optimal level.
As soon as the temperature drops below the programmed temperature, the heating function is automatically activated.
VIII. Changing the remote control batteries
Remote control power supply: 1 x 3 V (CR 2430 battery) (2 batteries supplied)
Battery life: 2 years approx
The remote control is supplied with 2 batteries. Only one battery is required (pull off the plastic strip to make it useable).
The other battery is a spare.
- When the battery runs out, the
- Take the remote control off the wall.
- On the back of the remote control, push the used battery down using a screwdriver (see diagram opposite).
- Pull the strip from the spare battery, which will then be ready for use.
- Remember to buy a replacement for the spare battery.
IX. Discharging condensate
Your conditioner was designed to allow condensate to be discharged (discharge pipe located under the conditioner's
housing) either inside the cellar, if the humidity level is too low, or outside the cellar.
Simply pass the pipe through the wall to discharge the condensate into the room next to the conditioner housing.
Ensure that the piping is not kinked.
Vacuum the 4 air entry and exit grids at least twice a year, ensuring that you first unplug the conditioner. Please note that a refrigeration engineer must be employed for
a more thorough cleaning of your appliance's internal elements (every two years).
Dimensions
Power
in mm
supply
W385 x D322
230 V
Inoa 25
x H1250
/ 50 Hz
W385 x D322
230 V
Inoa 50
x H1250
/ 50 Hz
* in a very well insulated room - ** for an internal temperature of 12 C and an external temperature of 32 C.
*** for an internal temperature of 12 C and an external temperature of 25 C.
Supplied with 3.50 m power lead without plug.
pictogram flashes on the remote control's display.
8/ EVERYDAY MAINTENANCE
9/ TECHNICAL SPECIFICATIONS
Sample
Cooling
Weight
volume m
3
capacity W
Kg
Up to
600W**
43 Kg
25m
3*
Up to
1200W**
46 Kg
3*
50m
Electrical
Heating
Refrigerant
power W
resistance W
550W**
650W
R134a
(without CFC)
800W**
650W
R134a
(without CFC)
External
Consumption
temperatures
per 24h***
3,1kwh
-5°C to 35°C
4,1 kwh
-5°C to 35°C
12
GB

Publicité

loading

Ce manuel est également adapté pour:

Inoa 50