LEGEND:
F1: 5A fuse connected to the vehicle battery to power the side marker lights.
F2: 20A fuse connected to the service battery to power the fridge.
F3: 25A fuse connected directly to the service battery to power the litf bed.
F4: 20A/10A fuse connected directly to the service battery to power the Webasto (20A) o Combi (10A)
F5: 15A fuse connected to lights master switch to power the group of lights_1.
F6: 15A fuse connected to lights master switch to power the group of lights_2.
F7: 10A fuse connected directly to the service battery for igniting the fridge, to power the USB and to
the pump switch to power the water pump.
F8: 5A fuse connected directly to the service battery to power the wc, stove and the external light
switch to power the external light.
F9: 10A fuse
connected directly to the service battery to power the various utilities.
Attention:
When replacing faulty fuses, observe the correct amperage.
OPERATION:
Power activated from control panel:
The outputs for internal lights (lights_1 and lights_2), external light, pump are activated directly by
the relevant keys on the control panel.
-If the service battery voltage remains under 10,5V for over three minutes, the NE355 shunt
automatically turns off all the power for lights, pump. To recharge press the relevant keys on the
control panel. If the battery is still under 10,5V, it will be deactivated again after three minutes. In
this case is advisable to disconnect all loads with the battery main switch and recharge the
battery services within 2 days.
Car battery recharge:
If there is the main supply 230V, the shunt charges the car battery with a current of about 2A. The
charge is activated automatically when the battery voltage exceeds the services of the car battery.
Side marker signal:
The side-marker output can be activated with a negative control (negative) on the JP13 block, pin 5.
Services activated by D+:
(1)
The coupler relay and fridge relay are enabled immediately in one of these two conditions:
+key
KEY-ON
JP13 pin 1
+12V
(1)
The coupler relay recharges the service battery with the alternator when the engine is running.
The fridge relay powers the three purpose fridge at 12V when the engine is running.
With the engine running the external light automatically turns itself off.
(1)
If there is a connection between J14 and J15 the coupler relay is not enabled.
(presence of external DC / DC converter)
ATTENTION: DC / DC converter:
If you use the DC / DC converter to charge the services battery, make the
connection between J14 and J15.
In this mode the coupler relay (RE1) is not enabled when
If the vehicle not in use and the connection 230V is not present disconnect the battery service with
the battery main switch.
SHUNT NE355_T
+Alternator
G
JP13 pin2
+12V
+key
or
KEY-ON
JP13 pin 1
+12V
6
D+
D+
JP13 pin 6
on
the engine is running.