Télécharger Imprimer la page

GRE mini pool heating HPM30 Manuel D'instructions page 5

Masquer les pouces Voir aussi pour mini pool heating HPM30:

Publicité

WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES
 The power supply to the appliance must be protected by a dedicated 30 mA Residual Current Device (RCD),
complying with the standards and regulations in force in the country in which it is installed.
 Do not use any extension lead when connecting the appliance; connect the appliance directly to a suitable
power supply.
 Before carrying out any operations, check that:
 The voltage indicated on the appliance information plate corresponds to the mains voltage.
 The power grid must be adapted to the power requirements of the appliance, and is grounded.
 The plug (where applicable) is suitable for the socket.
 Do not disconnect and reconnect the appliance to the power supply when in operation.
 Do not pull on the power cord to disconnect it from the power supply.
 If the power cord is damaged, it must be replaced by the manufacturer, its technician or a qualified person
to guarantee safety.
 Do not perform maintenance or servicing operations on the appliance with wet hands or if the appliance is
wet.
 Before connecting the appliance to the power supply, check that the connection unit or socket to which the
appliance will be connected is in good condition and shows no signs of damage or rust.
 In stormy weather, disconnect the appliance from the power supply to prevent it from suffering lightning
damage.
 Do not immerse the appliance in water or mud; keep the circuit breaker away from water.
WARNINGS CONCERNING APPLIANCES CONTAINING REFRIGERANT R32
 R32 refrigerant is classed under category A2L as mildly flammable.
 Do not release R32 fluid into the atmosphere. These are fluorinated greenhouse gases, covered by the
Kyoto Protocol, with a Global Warming Potential (GWP) of 675 (European regulation EU 517/2014).
 The appliance must be stored in a well-ventilated location away from all ignition sources.
 Install the unit outdoors. Do not install the unit indoors or in an enclosed and non-ventilated outdoor
location.
 Do not use means for accelerating the defrosting or cleaning process other than those recommended by the
manufacturer.
 The appliance must be stored in a room without any permanent ignition source (such as open flames,
operating gas appliance or operating electric heating).
 Do not perforate or incinerate.
 Please note that R32 refrigerant may give off a certain odour.
 In order to comply with the applicable standards and regulations in terms of the environment and
installation, in particular French decree No. 2015-1790 and/or European regulation EU 517/2014, a leak test
must be performed on the cooling circuit at least once a year. This operation must be carried out by a
specialist certified to test cooling appliances.
 Please keep the display controller in a dry area, to protect the display controller from being damaged by
humidity.
MAINTENANCE: WARNINGS CONCERNING APPLIANCES CONTAINING R32 REFRIGERANT
 When servicing the appliance, the composition and state of the heat transfer fluid must be checked, as well
as the absence of any traces of refrigerant.
 During the annual appliance sealing test in accordance with applicable legislation, the high and low pressure
switches must be checked to ensure that they are securely fastened to the refrigerant circuit and that they
cut off the electrical circuit when tripped.
 During maintenance work, ensure there are no traces of corrosion or oil around the cooling components.
 Do not braze or weld the pipe if there is refrigerant inside machine. Please do not charge the gas when in a
confined space.
- 3 -

Publicité

loading

Ce manuel est également adapté pour:

Mini pool heating hpm20Mini pool heating hpm40