Overhead Installation
When hung, the device must always be secured with a secondary attachment e.g. a
safety cable (not incl.).
Never stand directly below the device when it is being mounted, removed or
serviced. Have a qualified technician check the device once a year and once before
you bring it into service.
Overhead mounting requires extensive experience: calculating workload limits,
determining the installation material to be used... Have the material and the device
itself checked regularly. Do not attempt to install the device yourself if you lack
these qualifications as improper installation may result in injuries.
For truss mounting, use an appropriate clamp (not incl.) and fit an M10 bolt through
the centre of the (folded) bracket.
4.3
Secondary Suspension
Hanger
Where a hanger is provided, the bearing parts of the hanger shall be capable of
supporting ten (10) times the weight of the luminaire without permanent deformation
and shall be manufactured from non-combustible materials such as steel or its
equivalent.
Accessories
The design of the luminaire shall be such that removable accessories, e.g. colour frames
and barn doors, when properly inserted, cannot fall out of the luminaire.
Secondary Suspension
A secondary suspension shall be provided for the luminaire, except where the luminaire
is arranged for floor mounting or if it is intended for handheld use. The secondary
suspension shall be designed and mounted in such a way that in the event of a failure of
the primary suspension, no part of the luminaire can fall. The secondary suspension
must withstand a 30 cm vertical drop for 30 times.
4.4
Connection
Have a qualified electrician carry out the electric connection.
Connect the device to the mains with the power plug. All devices must be powered
directly off a grounded switched circuit. Do not connect to a dimmer pack.
The installation has to be approved by an expert before the device is taken into
service.
5.
Overview
Refer to the illustrations on page 2 of this manual.
1
2
3
4
5
V. 03 – 15/10/2018
DMX input
DMX output
on-off switch
power input + fuse
power output
HQLP10030
6
7
8
9
7
battery life LEDs
display
microphone
control panel
©Velleman nv