Setting temperature
Use the function selection buttons (F) to select temperature setting. Use the - and +
buttons to then select temperature setting 1-10. The temperature obtained depends on
the max. temperature set, i.e. which program has been set. Temperature can be adju-
sted whilst taking a sauna if required. Different temperatures apply to Combi heaters.
See humidity settings.
Max. tempera-
ture
52 °C
55 °C
EN
90 °C
110 °C
Once the temperature has been set and the heater started, the set temperature will be
indicated continuously and actual temperature will be indicated by a flashing indicator.
Once the actual temperature reaches the set value, the flashing will stop.
Setting delayed start
You can set a time when the heater is to start after a certain time. A door contact must
be connected for this purpose (see "Connecting door contact and its function"). Use
the function selection buttons (F) to select the timer symbol. Use the – and + buttons
to select the number of hours until the heater is to start (1-10 hours). Activate delayed
start by pressing the Start button (C).
The indicator symbol for delayed start will light (field B) and the time delay diode will
start to flash. The flashing indicator will count down and show the actual time remai-
ning until the heater starts. Once the heater starts, the panel will switch to showing set
temperature automatically.
The door contact to be used is Tylö item number 90908035.
Set temperature (approx. value, °C)
1
2
3
30
33
35
30
33
36
40
46
51
65
70
75
48
4
5
6
37
40
42
38
41
44
57
62
68
80
85
90
7
8
9
44
47
49
47
49
52
73
79
84
95
100
105
10
52
55
90
110