EN
PROGRAMMING
The CD2131PL digitizer module included in the videokit is programmed
with the same calling code as the internal station (100) and therefore
needs no programming. The encoder module must be programmed
as illustrated below only if you want to change some functions or add
additional devices to the videokit:
1) enter programming mode
2) insert code of desired programming
3) insert required address or functional code
4) exit programming mode
Notes
- In any situation it would be possible to exit the programming phase
following the instructions reported on paragraph 4.
- To proceed with other programming repeat the phases 2 and 3.
Enter programming mode
1)
Move the jumper J1 from 2-3 to 1-2 position; a programming tone will
confirm the correct operation.
Position of jumper J1
2-3 = operating mode
Insert code of desired programming
2)
On the micro-switches MS1
and MS2 set the code corre-
sponding to the programming
operation you wish to enter as
reported on table 1 of page 27
(codes 1A, 2A, 1B, 2B, 1C,
1E and AA).
Press the programming but-
ton SW.
Insert required address or functional code
3)
On the microswitches MS1 and MS2 set the address you wish to enter
in accordance with the cross-references reported on table 3 of pages
77, 78 and 79.
For the codes to enter see table 2 of page 28 (code 2B).
Press the programming button SW.
- Repeat phases 2 and 3 until you have completely programmed the
Digital Encoder.
- Any time you press the SW button an acknowledge or error tone will
warning you whether the entered code is correct or not; in case of
incorrect code you must enter again the correct one.
4)
Exit programming mode
To exit the programming phase it is necessary to set OFF all the
microswitches MS1 and MS2 and move back the jumper J1 from 1-2
to 2-3 position.
MS1
MS2
ON
ON
1 2 3 4
1 2 3 4
Position of MS1, MS2 microswitches and jumper J1
to exit the programming phase.
1-2 = programming mode
Table 1
Selection code of the pro-
gramming
MS1
MS2
1A
1
A
MS1
MS2
2A
*
2
A
MS1
MS2
1B
1
B
MS1
MS2
2B
2
B
MS1
MS2
ON
1C
1 2 3 4
1
C
MS1
MS2
1E
1
E
MS1
MS2
AA
A
A
Codes used to deactivate the camera upon call of 2 user groups
MS1
MS2
4E
4
E
MS1
MS2
5E
5
E
MS1
MS2
6E
6
E
MS1
MS2
7E
7
E
* This programming is useful when the push button panel has more
buttons than the connected users and to prevent the case when, by
pressing an unused button, the system gets still busy.
- 27 -
Address or function to be programmed
User address associated to the first button.
Codes from 1 to 200 (see table 3 of pages
77, 78 and 79). Default 100.
User address associated to the last button.
Codes from 1 to 200 (see table 3 of pages
77, 78 and 79). Default 200.
Address of the external door station. Codes
from 231 to 250 (see table 3 of page 79).
Default 231.
System programming (see table 2).
Settings for operations with a door keeper
echanger. Enter address 201 if the door
station operates with 1 or more main door
keeper exchangers or the address 210 if
the door station operates with 1 or more
secondary door keeper exchangers (see
table 3 of page 79).
Address associated with terminals EC-EM
Set the device back to factory settings.
Code 85 (see table 3 of page 77).
First address in group 1 (see codes of table
3 on pages 77, 78 and 79)
Last address in group 1 (see codes of table
3 on pages 77, 78 and 79)
First address in group 2 (see codes of table
3 on pages 77, 78 and 79)
Last address in group 2 (see codes of table
3 on pages 77, 78 and 79)