RS-232C command table
How to read the command table
Command:
Command field (See page 25.)
Direction:
W When the "Parameter" is set in the parameter field (see page 25), the command functions as described
under "Control/Response Contents".
R The returned value indicated under "Reply" can be obtained by setting "????", "
(repeater control) in the parameter field (see page 25).
Parameter:
Parameter field (See page 25.)
Reply:
Response (Returned value)
*:
"Yes" indicates commands which can be used in power standby mode.
TIPS
• To specify the horizontal/vertical positions for vertical orientation, specify the values for horizontal orientation.
Power control/Input mode selection
Function
POWER CONTROL
INPUT MODE SELECTION
SCREEN menu (PC2/PC3)
Function
AUTO
CLOCK
PHASE
POSITIONING
POSITION OF
THE LONGEST
DIRECTION
POSITION OF
THE SHORTEST
DIRECTION
RESET
Command
Direction
Parameter
POWR
W
0
1
R
INPS
W
0
1
2
3
4
6
7
R
Command
Direction
Parameter
ASNC
W
1
CLCK
WR
0-255
PHSE
WR
0-63
HPOS
WR
0-500
VPOS
WR
0-100
ARST
W
1
Controlling the Monitor with a PC
Reply
Control/Response contents
Switches to standby mode.
Returns from standby mode.
0 Standby mode
1 Normal mode
2 Input signal waiting mode
Toggle change for input mode
Terminals not selected in DVI SELECT/BNC SELECT cannot be
selected.
PC1 DIGITAL
"ERR" when AV (DIGITAL) is selected for DVI SELECT.
PC2 ANALOG
AV2 COMPONENT
"ERR" when PC (ANALOG) is selected for BNC SELECT.
AV3 VIDEO
PC3 ANALOG
"ERR" when AV (COMPONENT) is selected for BNC SELECT.
AV1 DIGITAL
"ERR" when PC (DIGITAL) is selected for DVI SELECT.
1 PC1 DIGITAL
2 PC2 ANALOG
3 AV2 COMPONENT
4 AV3 VIDEO
6 PC3 ANALOG
7 AV1 DIGITAL
Reply
Control/Response contents
0-255
0-63
0-500 A maximum value depends on a resolution.
0-100
?" or "???+"
*
Yes
Yes
*
No
No
No
29