Commands for ID control
The command examples shown on this page assume the
following connection and ID number set up.
ID number: 1
ID number: 2
IDST ......... A monitor receiving this command sets its own ID
number in the parameter field.
Example:
IDST0001
OK
001
The ID number of this monitor is set to 1.
TIPS
You can automatically assign ID numbers by using the IDST
command with the Repeater control (see "Repeater control"
on page 28).
For example, using the command "IDST001+" automatically
sets the ID numbers, as shown below.
[Example]
ID number: 1
ID number: 2
IDST001 +
ID setting command with repeater control
WAIT
OK
001
"OK" response from ID number: 1
OK
002
"OK" response from ID number: 2
OK
003
"OK" response from ID number: 3
OK
004
"OK" response from ID number: 4 (End)
IDSL ........The parameter of this command sets the ID number
of the monitor. The monitor is subject to the next
command.
Example:
The next command is for the monitor with
IDSL0002
ID number: 2.
WAIT
Searching for monitor with ID number: 2
OK
002
Found monitor with ID number: 2
Sets volume of monitor with ID number:
VOLM0030
2 to 30.
WAIT
Processing
OK response from monitor with ID
OK
002
number: 2
VOLM0020
Sets volume to 20.
The volume of the monitor with ID
OK
001
number: 1 (the one directly connected
to the PC) is set to 20.*
* The IDSL command is effective only once, for the
immediately succeeding command.
IDLK ........The parameter of this command sets the ID
ID number: 3
ID number: 4
ID number: 3
ID number: 4
IDCK ........Provides screen display of the ID number currently
Controlling the Monitor with a PC
number of the monitor. The monitor is subject to all
subsequent commands.
Example:
Following commands are for the monitor
IDLK0002
with ID number: 2.
WAIT
Searching for monitor with ID number: 2
OK
002
Found monitor with ID number: 2
Sets volume of monitor with ID number:
VOLM0030
2 to 30.*
WAIT
Processing
OK
002
Sets volume of monitor with ID number:
VOLM0020
2 to 20.*
WAIT
OK
002
IDLK0000
Canceling fixed ID number setting
WAIT
Canceling IDLK
OK
002
Cancelation complete
VOLM0010
The volume of the monitor with ID number: 1
OK
001
(the one directly connected to the PC) is set
to 10. (IDLK is canceled.)
* The IDLK command remains effective until it is
canceled, or power is shut off.
assigned to a monitor, and the ID number currently
set for IDLK (if any).
Example:
(After executing IDLK0002)
IDCK0000
(Parameter has no meaning.)
Returned response. The ID
ID : 001
IDLK : 002
number is also displayed on the
monitor screen.
Repeater control (If a command
IDCK000 +
is used with repeater control, ID
WAIT
designation using IDSL or IDLK is
ID : 001
IDLK : 000
canceled.)
ID : 002
IDLK : 000
ID : 003
IDLK : 000
ID : 004
IDLK : 000
27
E