Hansgrohe iControl mobile 15941180 Mode D'emploi / Instructions De Montage page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
Water connection DN 20 Warm wa-
ter
Water connection DN 20 Cold water
Turn on water
turn off water
From • the function is guaranteed.
The waste drain performance must be
more than 50 l/min.
> 50 l/min
Waste
Raindrain
X
Center shower tub
Transformer:
Light relay:
12
English
Symbols
Transformer
Receiver
Coding plug
230V
12V
Empty pipe
Light control 27189000 (not includ-
ed!)
Light relay Rainmaker
Fittings
The external transformer provides 50 VA. The trans-
former must be installed in the dry area (protected
zone 3). The transformer can be installed together
with the receiver in a plastic housing, while ob-
serving EN/IEC 60335-1. (dimensions approx.
250 x 160 x 92 mm, not included in the delivery.)
The included cable allows the installation of the
transformer, up to 7 m away from the receiver. For
this, you must provide an empty pipe EN35 (not
included in the delivery). This empty pipe must be
affixed at least every 500 mm and the bending
radius must be greater than 100 mm.
The secondary line of the transformer, which is
approx 7 m long, must not be shortened. The un-
used line length should be stored near the safety
(for models with integrated lights only)
The max. load for the light relay is 12 V AC /
80 W.
Do not use with 230 V power.
Assembly see page 133 + 135
transformer Rainmaker
Site-supplied preinstalled 12 Volt con-
nection for light (max. 80 W)
Potential equalisation
Silicone (free from acetic acid!)
transformer. A damaged connecting line must not
be replaced. The transformer may no longer be
used.
A damaged connecting line must not be replaced.
In case of a defective mains cable, the entire cable
including the transformer must be replaced by a
trained electrician.