Product Dimensions

12
3
/
"
8
(31.4 cm)
4
13
/
"
16
(12.2 cm)
11½"
(29.2 cm)
5
/
"
1
16
(12.8 cm)
Range
DIM A
Hood mod.
EAR628SS
28½" (72 cm)
EAR134SS
34½" (87 cm)
EAR140SS
40½" (102 cm)
EAR146SS
46½" (117.5 cm)

Venting Requirements

Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or enclosed areas.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should
be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system and use
furnace duct tape to fully seal joint connection.
Use caulking to seal exterior wall or roof opening around the cap.
The size of the vent should be uniform.
34½", 40½" & 46½"
models wiring knockout
C
B
A
DIM A
+ spacers
30" (76.2 cm)
24
36" (91.44 cm)
29
42" (106.68 cm)
29
48" (121.92 cm)
29
9
/
" (25.11 cm)
7
8
28½" model
wiring knockout
E
*HOOD SPACER
¾"
(1.9 cm)
DIMENSIONS
DIM B
DIM C
mounting holes
/
" (61.8 cm)
22" (56 cm)
5
16
13
/
" (75.76 cm)
27½" (70 cm)
16
/
" (75.76 cm)
27½" (70 cm)
13
16
/
" (75.76 cm)
27½" (70 cm)
13
16
Cold weather installations
An additional back draft damper should be installed to mini-
mize backward cold air flow as part of the vent system.
A thermal break should be installed to minimize conduction of
outside temperatures as part of the vent system.
The damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Make-Up air
Local building codes may require the use of make-up air sys-
tems when using ventilation systems greater than specified
CFM of air movement. The specified CFM varies from locale
to locale. Consult your HVAC professional for specific require-
ments in your area.
6
11"
(28 cm)
22" (55.9cm)
D
22" (55.9cm)
DIM D
DIM E
mounting holes
11" (28 cm)
14" (36 cm)
10
1
/
" (25.6 cm)
17" (43.6 cm)
16
10
/
" (25.6 cm)
20" (51.2 cm)
1
16
10
/
" (25.6 cm)
23" (58.8 cm)
1
16