FITTING THE POWER SUPPLY CABLE
GATE OPENING INWARDS
IMPORTANT: the terminals of M1 (A1, B1, C1) and M2 (A2, B2, C2) motors in the controller correspond to:
- M1 = Dardo on 1st gate leaf to open and in pedestrian mode if selected.
!
- M2 = Dardo on the gate leaf delayed in opening.
IMPORTANT: on single gate installations where only one operator is mounted, it is sufficient to connect
!
the motor to M1 and bridge B1 with B2, while A2 and C2 terminals are not connected.
Dardo
terminals
A
B
A2 B2 C2
Dardo M2
power supply
electromechanical operator for swinging gates
Once the electrical
connections are finished,
tighten the gland locknut
Let the cable dangle free
avoiding sharp bending
Dardo M2
C
ELPRO 42
Dardo M1
Dardo
terminals
A
A1
B1 C1
Dardo M1
power supply
23
Terminal block for
electrical connections
A
B
C
Pic. 14
B C
Pic. 15