DARDO 424
DARDO 424
MAIN COMPONENTS AND ELECTRICAL WIRING DIAGRAM OF THE SYSTEM
Lay the cable pipes into the ground and make sure they are suitable to the soil nature and comply with the diagram below.
1
2
4
3
5
LEGEND
1 - Dardo 424 motor operator: 4G x 1,5 mm² cable
2 - Photocell transmitter (2 x 0,5 mm²)
3 - Ground stop in open gate position (not supplied with the equipment)
4 - Photocell receiver (4 x 0,5 mm²)
5 - Radio transmitter
6 - Ground stop in closed gate position (not supplied with the equipment)
7 - Inspectable junction pit
8 - Keyswitch or push buttons panel (4 x 0,5 mm²)
9 - Controller with VIX 53/1R plug-in radio receiver card
10 - Flasher with aerial (2 x 0,5 mm² + RG58)
Type of cables to be used (not included with the equipment):
Motor power supply, safety and command accessories: FROR CEI 20-20 CEI EN 50267-2-1
Aerial: RG58.
NOTE: with distances longer than 50 m increase cable section according to the actual absorption requirements of the various
devices in compliance with the CEI EN 60204-1 norms.
electromechanical operator for swinging gates
Pic. 3
Indicative general layout. It is the installer's care and responsibility to
lay the cable pipes in the most suitable way for the electrical
connections.
6
2
The system is to be 230 V - 50 Hz power
supplied through a 0,03 A
!
magneto-thermal differential circuit
breaker (beyond 100 m a 2,5 mm² section
is recommended).
The all installation is to be grounded.